Front matter

第 1 段问这一段

PINPOINT enables non-destructive nanoscopic quality control of individual lipid nanoparticles and their mRNA cargo

第 2 段问这一段

Nils Walter University of Michigan https://orcid.org/0000-0002-7301-1275 Pavel Banerjee University of Michigan https://orcid.org/0000-0002-7968-8105 Tanmay Chatterjee University of Michigan Alexander Johnson-Buck University of Michigan Nicole Wrubel University of Michigan Armin Ahnoud University of Michigan Article Keywords:

第 3 段问这一段

Posted Date: November 5th, 2026 DOI: https://doi.org/10.21203/rs.3.rs-11342178/v1 License:   This work is licensed under a Creative Commons Attribution 4.0 International License. Read Full License Additional Declarations: There is NO Competing Interest.

第 4 段问这一段

PINPOINT enables non-destructive nanoscopic quality control of individual lipid nanoparticles and their mRNA cargo

第 5 段问这一段

Pavel Banerjee1,3, Tanmay Chatterjee1,3, Alexander Johnson-Buck1, Nicole E. Wrubel1, Armin Ahnoud1, & Nils G. Walter1,2* 1Single Molecule Analysis Group, Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA 2Center for RNA Biomedicine, University of Michigan, Ann Arbor, MI 48109, USA 3These authors contributed equally: Pavel Banerjee, Tanmay Chatterjee e-mail: nwalter@umich.edu

摘要Abstract

第 6 段问这一段

Quality control of lipid nanoparticles (LNPs) is central to development of mRNA therapeutics, yet ensemble measurements obscure critical heterogeneity in particle morphology and mRNA cargo loading. Here we introduce PINPOINT (Profiling Individual Nanoparticles with Precise Observation of INternalized Therapeutics), a single-particle nanoscopy platform for nondestructive, multiparametric profiling of preformulated LNP samples. Super-resolution imaging with Nile Red resolves size and morphology, while an optimized permeabilization strategy provides selective access to encapsulated mRNA without compromising LNP integrity. Singleparticle fluorescence measurements, including RiboGreen and sequence-specific probes, enable quantification and validation of mRNA loading and identity. Comparative analyses of bare and encapsulated mRNA reveal kinetic and structural features, exposing heterogeneity masked by bulk assays. By integrating structural and molecular readouts at the single-particle level, PINPOINT establishes a quantitative framework for assessing of LNP composition and payload distribution, offering actionable insights for improving batch consistency and guiding the rational design of next-generation mRNA delivery systems.

第 7 段问这一段

Messenger RNA (mRNA) therapeutics have transformed modern medicine, enabling vaccines, protein replacement and gene therapy1-3. Their clinical success depends on efficient mRNA encapsulation and delivery, a challenge addressed by lipid nanoparticles (LNPs) that underpin FDA-approved nucleic acid medicines, including siRNA drugs and several COVID-19 vaccines4,5. Stable, potent LNPs are typically formulated from ionizable lipids, phospholipids, cholesterol and polyethylene glycol conjugates6-8. The performance of these LNP-based therapeutics is highly sensitive to formulation and manufacturing variables, including microfluidic mixing and pHdriven assembly9-14. While advances in production have improved control over size and morphology, they also underscore how strongly efficacy, toxicity, and biodistribution depend on physicochemical attributes, making rigorous characterization essential for formulation development15-20.

第 8 段问这一段

Routine LNP analytics remain dominated by bulk measurements such as dynamic light scattering (DLS), nanoparticle tracking analysis (NTA) and the Quant-iT RiboGreen assay, which report population averages and cannot resolve particle-to-particle variability in size, shape or cargo encapsulation21,22. Thus, these methods can mask heterogeneities, such as the presence of substantial fractions of empty, sparsely loaded particles, that may influence therapeutic outcomes22-24. Electron microscopy provides high-resolution structural information but typically requires sample preparation that perturbs native LNP states and complicates structure-function analysis, and cannot report on the sequence of any RNA cargo19,25. Fluorescence-based singleparticle approaches can distinguish loaded from empty particles23,27, but stable labelling may impact loading or efficacy and thus may be incompatible with release testing and scale up of the particles, and intensity-based readouts rarely report on cargo integrity or precise sequence identity26-28. Critically, direct access to encapsulated mRNA often requires disruptive processing that compromises LNP structure and obscures relationships between morphology, loading and integrity20,23,27. These limitations motivate non-destructive platforms that can jointly quantify morphology and cargo loading, identity and integrity in individual LNPs.

第 9 段问这一段

To address these gaps, we developed PINPOINT (Profiling Individual Nanoparticles with Precise Observation of INternalized Therapeutics), a single-molecule nanoscopy platform for multiparameter profiling of individual LNPs, including preformulated samples with defined mRNA cargo compositions. PINPOINT combines super-resolution Nile Red imaging for sizing and morphology with controlled Triton X-100 (TX-100) permeabilization that enables probe access to encapsulated mRNA while preserving measurable particle morphology. Single-particle RiboGreen imaging and sequence-specific fluorescent probes quantify mRNA loading and assess cargo identity and regional accessibility within surface-captured particles. By linking particle morphology with single molecule kinetic profiling from bare and encapsulated mRNA, PINPOINT reveals heterogeneity masked by bulk methods, enabling quantitative quality control to support batch comparison, formulation optimization and the rational design of next-generation mRNA delivery systems.

Abstract / Fingerprinting lipid nanoparticles for quality control

第 10 段问这一段

To meet the need for a non-destructive, amplification-free approach that reads out multiple orthogonal attributes from preformulated LNP samples without covalent modification of their components, we developed PINPOINT, a nanoscopic fingerprinting platform implemented on a commercial total internal reflection fluorescence (TIRF) microscope29-32. The workflow addresses quality attributes relevant to mRNA–LNP formulation and manufacturing, progressing from particle morphology to cargo quantification and identity (Fig. 1a). PINPOINT immobilizes LNPs on a passivated glass coverslip via anti-PEG capture without covalent modification33. Surfacecaptured LNPs are then interrogated using three complementary modalities (Fig. 1a, b): superresolution Nile Red imaging to assess LNP size and morphology34,35, single-particle RiboGreen fluorescence to quantify RNA content as a proxy for mRNA copy number36, and sequence-specific fluorescent oligonucleotide probes for highly specific identification of cargo through repeated transient binding that yields a kinetic fingerprint distinct from nonspecific interactions31,32. Probe and capture sequences are listed in Supplementary Table 1.

第 11 段问这一段

We developed and validated PINPOINT using three externally prepared LNP formulations (LNP1001, LNP1002, and LNP1004) with distinct mRNA cargo compositions containing mRNA1, mRNA2, or both cargos (Supplementary Table 2), alongside a commercially sourced cargo-negative LNP formulation (LNP-ALC0315) as an RNA-negative control (Supplementary Fig. 1). Cargo identification is challenging for conventional in situ hybridization approaches because the mRNAs share ~98% sequence identity. To increase sequence discrimination, we used a kinetic fingerprinting readout based on transient binding of short probes (8–9 nt), whose interaction kinetics are highly sensitive to small differences in sequence31. To minimize perturbation of LNPs, we further opted for isothermal in situ hybridization under mild conditions; however, a significant obstacle arises from the substantial secondary structure across the ~2.1-kb transcripts, which can occlude binding sites and introduce structure-dependent heterogeneity37. We therefore targeted a short window (nt 650–658) that would allow discrimination between the two closely related mRNA cargos and used a local DNA-tiling strategy, placing three unlabelled, fully complementary 40-nt tiles upstream and three downstream of the probed site to reduce local folding and stabilize probe access (Fig. 1c and Supplementary Fig. 2)38. Because cargo is sequestered within the LNP interior, we paired tiling with a mild, optimized TX-100 permeabilization that permits probe entry while preserving overall particle contents and morphology (Fig. 1d)39,40. This assay design forms the foundation for the remaining sections, in which we quantify LNP morphology, map a non-destructive permeability window, and identify and interrogate encapsulated mRNA at the single-particle level.

Abstract / Super-resolution imaging reveals LNP size and morphology

第 12 段问这一段

Particle size is a critical quality attribute for LNP performance and is typically reported as a hydrodynamic diameter by DLS29,30, but as an ensemble technique DLS has limited sensitivity to minor subpopulations and does not directly report on particle morphology19. We therefore implemented a super-resolution module within PINPOINT to quantify LNP size and morphology directly from individual particles using Nile Red, a fluorogenic dye whose emission is enhanced in hydrophobic environments, based on the PAINT technique34,35. Repeated association and dissociation of Nile Red at the LNP interface produces temporally sparse fluorescence bursts that enabled particle detection and nanoscopic reconstruction from localizations of individual binding events (Fig. 2a)31,32. LNPs were surface-captured via an anti-PEG antibody on passivated coverslips33 and analyzed using localization-based reconstruction (Methods; Supplementary Figs. 3, 4)31,32,34. Assay conditions were optimized to preserve sparse-event kinetics and minimize background (Extended Data Fig. 1a, b). Nile Red imaging yielded bright puncta for captured LNPs, whereas no-LNP blank controls, containing Nile Red and the same surface chemistry but no added LNPs, exhibited only sparse short-lived events with weak signal, likely due to residual surface binding of the dye (Fig. 2b and Extended Data Fig. 1c). For each bright particle accepted, localizations were compiled into a super-resolution reconstruction (Fig. 2c), from which we extracted particle-resolved diameter, area and circularity index34. Particle diameter distributions from LNP samples showed far more particles than blank measurements (Fig. 2d), suggesting that the majority of signal arises from LNPs rather than background binding or Nile Red aggregates. Within single fields of view, PINPOINT resolved distinct size classes consistent with subpopulations masked in bulk measurements (Extended Data Fig. 1d).

第 13 段问这一段

We applied this assay to four LNP batches (LNP1001, LNP1002, LNP1004, and LNP- ALC0315). PINPOINT mean diameters agreed closely with DLS while additionally providing particle-level morphology distributions and representative super-resolution reconstructions of individual particles (Fig. 2e and Supplementary Table 3; Extended Data Fig. 1e), which were predominantly circular under these conditions. To test sensitivity to handling-induced structural changes30,41, we subjected LNP1001 to repeated freeze–thaw cycling between liquid nitrogen and a 37°C water bath. Although untreated LNP1001 particles already showed some shape heterogeneity, with circularity indices distributed below the ideal value of 1.0, freeze–thaw stress broadened this distribution and increased the fraction of visibly non-circular particles in superresolution reconstructions. DLS and PINPOINT both reported a shift from an apparently unimodal to a bimodal size distribution (Fig. 2f, Extended Data Fig. 1f), while PINPOINT additionally provided particle-resolved shape information, revealing an emergent non-circular subpopulation that was not apparent from DLS alone (Fig. 2f and Supplementary Table 3).

Abstract / Quantifying LNP permeability and cargo access

第 14 段问这一段

Bulk assays can estimate RNA content in LNP formulations, but they typically rely on detergentmediated lysis, precluding direct measurement of encapsulated mRNA accessibility while retaining particle-level morphological information36,39. To enable non-destructive cargo access at the single-LNP level, we incorporated a controlled permeabilization module into PINPOINT using mild surfactant (TX-100) conditions, together with fluorescence readouts of RNA accessibility (Fig. 3a). By operating below the critical micelle concentration (CMC) of TX-100—i.e., at concentrations of 0.005–0.01% v/v—we aimed to modulate permeability without driving full micellar solubilization39,40, and used RiboGreen as a static-access reporter complementary to a kinetic readout from mRNA-specific probes. We first defined a TX-100 operating window that increased RNA accessibility while preserving LNP morphology. In bulk spectra of LNP1001 with RiboGreen, fluorescence rose sharply over a narrow TX-100 range, consistent with a transition from an essentially impermeable state to one in which encapsulated RNA is dye-accessible (Fig. 3b and Extended Data Fig. 2a). This transition guided subsequent experiments within the 0.005– 0.01% regime, centered at 0.008% v/v. Under matched imaging conditions, RiboGreen TIRF revealed puncta only within this window, indicating surfactant-assisted access to internal RNA (Fig. 3c (ii, iv)). Importantly, Nile Red super-resolution sizing showed no significant change in LNP diameter across optimized TX-100 concentrations, whereas higher surfactant levels produced disruption consistent with dissolution, leading us to avoid these levels (Fig. 3c). Thus, TX-100 can be tuned to increase cargo accessibility while maintaining particle morphology at the resolution of our nanoscopy assay.

第 15 段问这一段

Cargo access was reversible and could be toggled by TX-100 availability: removing TX-100 abolished RiboGreen signals, as well as those of mRNA specific probes, and re-addition restored accessibility (Fig. 3d). Under static conditions, accessibility decayed over time across the operational window, as RiboGreen and mRNA-probe signals decreased while Nile Red-detected particle counts and size distributions remained stable (Fig. 3e and Extended Data Fig. 2b–d). DNA tile addition did not recover accessibility (Extended Data Fig. 2e), whereas replenishing surfactant by buffer exchange followed by fresh TX-100 or by repeated TX-100 addition restored and sustained access (Fig. 3f). These results support a sub-CMC regime in which TX-100 transiently increases permeability, but effective access declines over time due to surface adsorption39,40.

Abstract / Sequence specific detection of mRNA cargo

第 16 段问这一段

Sequence-specific single-molecule detection of intact mRNA is challenged by transcript length and secondary structure, which can occlude short probe binding sites and create time-dependent accessibility30. To demonstrate solutions for this challenge, we first established sequence-targeted detection on bare mRNA before moving to encapsulated cargo. We immobilized mRNA1 on passivated coverslips and interrogated a defined window (nt 650–658, Supplementary Fig. 2) with a short, Cy5-labelled 9-nt probe (Fig. 4a). Binding produced intensity time traces with repeated association and dissociation, which were idealized by hidden Markov modelling and filtered using kinetic criteria to reject nonspecific interactions (Methods; Fig. 4b and Extended Data Fig. 3a, general parameter sets in Supplementary Table 4)31,32,42,43. Under these conditions, blank chambers yielded near-zero (2.33 ± 0.47) accepted traces, supporting specific detection. However, without tiles, probe binding to mRNA1 was strongly intermittent, with burst-like periods of frequent events separated by extended intervals with little or no binding (Fig. 4c and Extended Data Fig. 3b), consistent with structure-gated switching between probe-accessible and probe-inaccessible states43. Fitting the cumulative distribution of burst durations yielded an accessibility transition rate constant (kacc→inacc = 0.027 s-1), suggesting that the underlying structural dynamics occur on a timescale of tens of seconds (Extended Data Fig. 3c).

第 17 段问这一段

To increase accessibility of the probe binding site, we implemented a local DNA-tiling strategy in which six unlabeled ~40-nt DNA oligonucleotides (tiles) adjacent, both upstream and downstream, to the probed site to disrupt competing secondary structure (Fig. 4d, Supplementary Fig. 2). As expected for a suppressed local mRNA secondary structure, tiling increased the frequency and temporal uniformity of specific probe binding and increased the number of accepted trajectory counts per FOV ~5-fold while maintaining low background (Fig. 4e and Extended Data Fig. 3d). Tile assembly affected assay performance, with thermal cycling and longer incubation increasing accepted counts, and pre-capture outperforming co-capture (Extended Data Fig. 3e; Supplementary Fig. 5). Tiling also suppressed the bursting behavior, yielding a Fano factor consistent with Poisson binding statistics and reducing unbound times (Fig. 4f, g and Extended Data Fig. 3f)43,44. Together, these results establish that short probes combined with kinetic fingerprinting can achieve sequence-targeted single-molecule detection of structured mRNAs, and that local tiling eliminates structure-gated binding to yield a more uniform, quantitative assay suitable for downstream cargo identification in LNPs.

Abstract / Probing encapsulated mRNA identity and regional accessibility

第 18 段问这一段

A key need in mRNA–LNP analytics is to assess encapsulated cargo identity and integrity in situ without destroying the particle and, with it, any information about population heterogeneity. Using the non-destructive permeability window defined above, we combined sub-CMC TX-100 (0.008% v/v) with sequence-specific kinetic fingerprinting probes to detect encapsulated mRNA in morphology-preserved, surface-captured LNPs by TIRF microscopy (Fig. 5a). Specificity derives from repeated binding and dissociation patterns with kinetic filtering to reject nonspecific interactions (Methods)32,42. We first targeted encapsulated mRNA1 in LNP1001 at the internal binding site (nt 650–658). Without tiles, probe binding was detectable but strongly intermittent, with burst-like periods separated by long inactive intervals (Fig. 5b (i, iii) and Extended Data Fig. 4a, b), consistent with structure-gated switching between probe-accessible and probe-inaccessible states. Encapsulation accentuated this gating relative to the bare mRNA1 (Extended Data Fig. 4df). Introducing local DNA tiling regularized access: tiled, encapsulated mRNA1 produced denser event trains (Fig. 5b (ii, iv)), binding statistics approached Poisson behaviour (Fig. 5b (v)), and kinetic fingerprints shifted toward more frequent interrogation (Fig. 5b (vi) and Extended Data Fig. 4c)43. Comparing tiled mRNA1 in bare versus encapsulated contexts further showed that encapsulation altered both bound and unbound time distributions, yielding shorter τon,med and longer τoff,med than bare mRNA1 (Fig. 5c), consistent with both reduced binding site accessibility and destabilization of hybridization inside LNPs containing both zwitterionic and ionizable cationic lipids.

第 19 段问这一段

This behavior generalized to a second sequence. Using an 11-nt probe against an internal binding site (nt 650–660) of mRNA2, PINPOINT detected both bare and LNP-encapsulated mRNA2 and revealed similar dependence of kinetics on LNP encapsulation as with mRNA1 (Fig. 5d and Supplementary Fig. 6). We then leveraged the short-probe strategy for multiplexed cargo identification. Dual-color probing enabled simultaneous detection of mRNA1 and mRNA2 within the same field of view (Fig. 5e). In a multiplexed detection experiment using three LNP formulations and an independent cargo-negative LNP-ALC0315 control, two-channel sequencespecific kinetic fingerprinting detected the expected cargo compositions: LNP1001 produced only mRNA1-specific signals, LNP1002 produced both mRNA1- and mRNA2-specific signals, LNP1004 produced only mRNA2-specific signals, and the LNP-ALC0315 control produced no accepted mRNA-specific signal above background (Fig. 5f). Colocalization analysis of LNP1002 suggests co-detection of both mRNAs in only a minority of particles (~25%), consistent with an approximate independent Poisson-loading model with an average of ~1 mRNA per LNP and with approximately twice as many accepted mRNA2-specific signals as mRNA1-specific signals under the assay conditions (Fig. 5f).

第 20 段问这一段

Toward developing a multi-region framework for assessing mRNA integrity (i.e., presence of full-length or nearly full-length RNAs in a given LNP), we implemented a two-color kinetic fingerprinting assay to simultaneously detect two distinct, well-separated sequences on the same mRNA. We designed an end-region probe for mRNA1 (nt 2033–2040), expected to be less structurally constrained than the internal site (Fig. 5g). End-region probing produced thousands of accepted traces per FOV with robust repetitive probe binding and dissociation (Fig. 5g (ii)), and two-color experiments enabled simultaneous internal- and end-region interrogation to provide a colocalization-based integrity readout within the same LNP population (Fig. 5h and Extended Data Fig. 5a, b). End-region probing showed higher apparent accessibility than middle-region probing, with a shorter median unbound dwell time (𝜏୭୤୤,୫ୣୢ ) and a higher total number of binding and dissociation events (ܰ ୠାୢ ) (Fig. 5i and Extended Data Fig. 5c), and dye-swap controls preserved this trend (Extended Data Fig. 5a, b). Fano factor analysis placed end-region behavior between the bursty middle-region signal (without tiles) and the Poissonian tiled condition (Extended Data Fig. 5d). Together, these results establish sequence-specific detection of encapsulated mRNA, resolve mixed-cargo formulations, and provide a site-resolved colocalization framework that could be further developed for assessing mRNA integrity within individual, morphology-preserved LNPs.

Abstract / mRNA

第 21 段问这一段

LNP quality control would benefit from combined information on particle morphology and cargo loading, because size and shape distributions can remain stable even when payload heterogeneity varies widely22-28. We therefore integrated orthogonal PINPOINT modules within a single assay framework, combining Nile Red PAINT nanoscopy for LNP size and shape with RNA fluorescence for cargo enumeration (Fig. 6a), to measure batch heterogeneity directly with singleparticle resolution. We first estimated mRNA copy number per LNP using single-particle RiboGreen staining intensity, reporting these values as fluorescence-calibrated copy-number estimates. Under matched imaging settings, bare mRNA1 provided a reference intensity distribution for one mRNA copy (Fig. 6b)20,23,24,27. At the level of individual surface-captured LNP-associated puncta, encapsulated mRNA1 signals in LNP1001 were broader and shifted to higher RiboGreen intensities than the single-mRNA reference, consistent with a mixture of particles containing one or more mRNA copies (Fig. 6b(iii)). We calibrated encapsulated intensity distributions against the bare-mRNA reference to estimate per-particle copy-number distributions (Fig. 6b(iv)). This calibration is justified by our prior bulk measurements indicating that RiboGreen staining intensity of mRNAs within LNPs permeabilized by 0.008% TX-100 is nearly identical to that of fully liberated mRNAs (Fig. 3b). Across LNP formulations, PINPOINT estimated an apparent mean of 2.0–2.3 RiboGreen-accessible mRNA copies among RiboGreenpositive particles, consistent with low average accessible mRNA content under the assumption that LNP-associated RiboGreen signal arises from encapsulated mRNA made probe-accessible after washing and permeabilization (Fig. 6b (v) and Supplementary Table 5)23,24.

第 22 段问这一段

To connect payload to morphology in the same population, we sequentially imaged RiboGreen and Nile Red in the same field of view and performed colocalization analysis (Fig. 6c and Extended Data Fig. 6a). Approximately 60% of Nile Red-detected LNPs colocalized with RiboGreen signal under the optimized permeabilization condition (Extended Data Fig. 6b), implying that ~40% of particles lacked detectable RiboGreen-accessible mRNA in this assay. This fraction is consistent with the expected RiboGreen-negative population under an approximate Poisson-loading model with a mean near one detectable mRNA per particle. At the particle level, plotting estimated copy number against Nile Red-derived diameter revealed weak (Pearson correlation coefficient R= 0.214) overall coupling between size and cargo content (Fig. 6d), with representative particles illustrating pronounced variability in mRNA copy number among similarly sized LNPs (Fig. 6d(ii)).20 We next replaced static RiboGreen readout with kinetic fingerprinting to quantify the particlelevel fraction of LNPs containing sequence-detectable cargo in a more sequence-specific manner by assessing colocalization of Nile Red and mRNA-specific probe binding (Fig. 6e and Extended Data Fig. 6c, d). For LNP1001, this approach yielded an apparent cargo-positive fraction of ~60%, based on the fraction of Nile Red-detected particles that also produced accepted mRNA1-probe trajectories (Fig. 6f). For a subset of mRNA1-positive LNPs, the mRNA-specific probe trajectories exhibited discrete multistep intensity levels, consistent with simultaneous binding of multiple probes to multiple accessible mRNA copies within the same particle (Supplementary Fig. 7). We therefore interpret these traces as qualitative support for multi-copy loading and as a potential trajectory-based route to cargo enumeration, rather than as the primary copy-number measurement. Finally, in an independently prepared formulation in which Cypridina luciferase (CLuc) mRNA was manually loaded into LNP-ALC0315, the same colocalization logic yielded a lower apparent cargo-positive fraction of 33% (Fig. 6g), consistent with the expected variability of manual loading19. Together, these synergized assays quantify copy-number distributions, cargo-positive fractions and morphology on the same single-LNP populations, enabling multiparametric batch fingerprinting for formulation and process optimization.

结论Conclusion

第 23 段问这一段

Lipid nanoparticles have enabled the rapid clinical translation of mRNA medicines, but their multicomponent, self-assembled nature makes them heterogeneous and sensitive to formulation scale up, manufacturing, and handling idiosyncrasies29,30. Because routine assays typically only report population averages or require disruptive processing19,20, ensuring batch consistency, linking particle structure to payload, and understanding attributes that influence efficacy and in vivo fate remain challenging. Here we introduced PINPOINT, a single particle nanoscopy platform that quantifies multiple critical quality attributes of mRNA–LNPs in a unified, operationally nondestructive workflow. Under the optimized sub-CMC TX-100 condition, LNPs retain Nile Reddetectable morphology rather than dissolving, while becoming sufficiently permeable to permit repeated access to encapsulated mRNA. PINPOINT provides multiparametric characterization of individual particles across particle size, circularity-based shape metrics, cargo identity, cargo accessibility, and loading. Super-resolution Nile Red imaging resolves LNP size and shape distributions and detects handling-induced changes such as emergent non-circular subpopulations after freeze–thaw stress, providing a potentially useful quality control measure in the event of variable sample handling or storage.

第 24 段问这一段

A controlled sub-CMC TX-100 permeabilization window enables probe access to encapsulated RNA while preserving particle morphology and reveals that cargo accessibility is dynamic and can be sustained by surfactant replenishment. Sequence-specific kinetic fingerprinting achieves high discrimination even for closely related mRNAs (~80% sequence identity in the probed region and 98% identity across the full-length sequence), and targeted DNA tiling regularizes structure-gated binding to improve quantification. Multi-region probing provides site-resolved information about RNA accessibility and a potential colocalization-based framework for assessing integrity within individual LNPs, and combined assays integrating Nile Red with RiboGreen or mRNA-specific probes estimate accessible mRNA copy-number distributions and particle-level cargo-positive fractions, exposing heterogeneous loading and co-detection patterns that are obscured by ensemble averaging 22-28. In the multiplexed detection study, cargo identity and loading metrics provided context beyond morphology-only signatures and distinguished the defined cargo compositions from an independent cargo-negative control. More broadly, PINPOINT reframes particle-toparticle variability from a confounder into a quantitative descriptor that can be tracked across batches, formulation changes and storage conditions, with direct relevance to quality control and rational design.

第 25 段问这一段

PINPOINT has limitations. The current implementation is not optimized for high-throughput screening or in-line manufacturing readout; present throughput is on the order of 104 particles per hour, and the current manual workflow requires approximately 3 h from sample preparation to result. PINPOINT also requires dilution of LNP samples to low-picomolar working concentrations to achieve spatially separated single-particle capture, so potential dilution-dependent effects should be controlled by matched handling conditions and reference formulations. Analysis also requires specialized software and careful parameterization for trace extraction, kinetic filtering and colocalization31,32. Detection depends on probe accessibility and background conditions, and permeabilization introduces time-dependent accessibility that must be controlled with care to limit false negatives due to re-sealing of membranes. The tiling strategy improves local access but adds an assembly step that may not be desirable in all settings38, and whose efficacy may be reduced by highly structured cargo RNAs. Throughput, speed and robustness could be improved using prefunctionalized imaging surfaces, faster capture chemistries, fluorogenic probes for faster imaging45,46, automated microfluidic buffer exchange for continuous introduction of TX-100, and greater standardization of calibration using reference materials. Analysis could also be further automated using machine-learning models trained on labels derived from hidden Markov modeling (HMM) and thresholding. Such models could reduce manual parameter tuning and improve resilience across conditions by classifying trajectories (specific versus nonspecific, high versus low confidence), flagging outliers, and automating particle morphology and colocalization calls from reconstructed features 47. Expanded probe panels and spectral demixing or kinetic encoding could further increase multiplexing without additional labelling of LNP components32. Overall, PINPOINT provides an integrated, amplification-free strategy for quantitative, sequence-resolved interrogation of individual mRNA–LNPs, enabling resolution of heterogeneity inaccessible to bulk methods to support batch consistency and optimization of RNA therapeutic delivery systems.

方法Methods

第 26 段问这一段

Materials All DNA and RNA oligonucleotides were purchased from Integrated DNA Technologies (IDT) with high-performance liquid chromatography purification. Oligonucleotide sequences are listed in Supplementary Table 1. Unless otherwise noted, oligonucleotides were dissolved in TE buffer (10 mM Tris-HCl, 0.1 mM EDTA, pH 8.0) to 100 μM, aliquoted and stored at −20 °C (DNA) or −80 °C (RNA). mRNA1, mRNA2, and LNP formulations LNP1001, LNP1002, and LNP1004 were provided as research materials; their cargo compositions and sample concentrations are summarized in Supplementary Table 2. LNP-ALC0315 was obtained from Cayman Chemical. Cypridina luciferase (CLuc) mRNA was synthesized in vitro using the HiScribe T7 mRNA with CleanCap Reagent AG kit (New England Biolabs, E2080S) according to the manufacturer’s instructions. Cy5-labelled mRNA was encapsulated at 50 ng μl⁻¹ using the LipidLaunch ALC0315 LNP Kit (Loadable) (Cayman Chemical, 702750). Monoclonal anti-PEG capture antibody (Abcam, ab170969) was used for LNP immobilization. Capture antibodies were bovine serum albumin (BSA)-free and azide-free to enable biotinylation using NHS–biotin reagents (where applicable). Nile Red (CAS 7385-67-3) and Triton X-100 (TX-100) (CAS X100-5ML) were purchased from Sigma-Aldrich (MilliporeSigma). The Quant-iT RiboGreen RNA Assay Kit and RiboGreen RNA reagent were purchased from Invitrogen (Thermo Fisher Scientific, R11490). All additional chemicals used for buffer preparation were obtained from Sigma-Aldrich or Thermo Fisher Scientific. DNA LoBind tubes (Eppendorf) were used for all experiments to minimize sample adsorption.

第 27 段问这一段

Biotinylation of capture antibody Monoclonal antibodies were biotinylated by reaction with biotin N-hydroxysuccinimidyl ester (Sigma-Aldrich, Catalog H1759−100), an amine-reactive NHS ester, in a solution containing a of 5:1 molar ratio of biotin: antibody, and incubated at room temperature for 1h in 1× PBS at pH 7.4 as described in previous studies32,43. The biotin-IgG conjugates were purified through Zeba Spin desalting columns (Thermo Fisher, Catalog 89882, 7K MWCO) according to the manufacturer’s protocol and underwent overnight dialysis (Slide-A-Lyzer Dialysis Cassette, Thermo Fisher, 3.5K MWCO) at 4 °C against 1× PBS, pH 7.4. Biotinylation was estimated with an electrophoretic mobility shift assay with or without excess streptavidin and ranged between 70% and 80%. The final capture antibodies were aliquoted and stored at −80 °C.

第 28 段问这一段

Cy5-labelled mRNA synthesis Cypridina luciferase (CLuc) mRNA was synthesized in vitro utilizing the HiScribe® T7 mRNA with CleanCap® Reagent AG kit (New England Biolabs, E2080S), in accordance with the manufacturer’s instructions. The kit-supplied linearized DNA template was used. To enable fluorescent labelling, 30% of the uridine triphosphate (UTP) was substituted with Cy5-UTP (Apexbio Technology LLC, B8333) during transcription. Following synthesis, the mRNA was purified with the MEGAclear™ Transcription Clean-Up Kit (Thermo Fisher Scientific, AM1908), again according to the manufacturer’s protocol.

第 29 段问这一段

Encapsulation of mRNA in LNP-ALC0315 Cy5-labelled CLuc-mRNA was encapsulated at a concentration of 50 ng/μL using the LipidLaunch™ ALC0315 LNP Kit (Loadable) (Cayman Chemical, 702750), following the provided protocol. After mRNA loading, the size distribution of the resultant LNPs was determined by dynamic light scattering (DLS) using the Dynapro Nanostar instrument (Wyatt Technology).

第 30 段问这一段

RiboGreen assay in steady state fluorescence Steady-state fluorescence spectra were acquired on a Horiba Scientific fluorometer (Fluoromax Plus-C) using quartz cuvettes. Blank spectra were collected in 1× PBS (pH 7.4; Gibco). For TX- 100 titrations, samples (final volume 200 μl) were prepared in 1× PBS (pH 7.4) containing LNPs (100 pM), RiboGreen reagent (1:200 dilution; Thermo Fisher Scientific) and Triton X-100 (TX- 100; 0–1% v/v, as indicated). Samples were excited at 480 nm and emission was recorded from 490 to 700 nm using 3 nm excitation and emission slit widths. Instrument signal and reference corrections were enabled (S1C and R1C), and spectra are reported as the ratio of sample detector to reference detector (S1C/R1C).

第 31 段问这一段

Dynamic Light Scattering Hydrodynamic diameter distributions of LNPs were measured by dynamic light scattering (DLS) using a DynaPro NanoStar (WDPN-10; Wyatt Technology). Samples were prepared at 100 pM in PBS (pH 7.4), and 10 μl of each sample was loaded for measurement. Data were collected and analysed using DYNAMICS software (Wyatt Technology). Particle diameters were determined by instrument software using cumulant analysis. For reporting an average diameter from the diameter histogram, we calculated the amplitude-weighted centroid using equation 1, ݀ =, (1) where ݀ ௜ is the diameter at bin ݅ and ܣ௜ is the corresponding histogram amplitude.

第 32 段问这一段

Preparation of glass slide surfaces for single-molecule microscopy Glass coverslips (No. 1.5, 24 × 50 mm; VWR, 48393-241) were PEG-passivated using a 1:10 molar mixture of biotin–PEG–SVA and mPEG–SVA (Laysan Bio; Biotin-PEG-SVA-5K-100MG and MPEG-SVA-5000-1g) following a standard protocol31,32. After PEGylation, coverslips were stored in a Coplin jar wrapped with aluminum foil in a nitrogen-purged cabinet and used within 4 weeks. For imaging experiments, multiwell chambers were constructed by cutting micropipette tips (Thermo Fisher Scientific, 02-682-261) approximately 1 cm from the wide end, discarding the narrow portion and placing the wide end in contact with the PEGylated surface to define a well. Wells were sealed to the coverslip using epoxy (Ellsworth Adhesives, 4001).

第 33 段问这一段

Single-molecule fluorescence microscopy All single-molecule experiments were performed using TIRF microscopy on an Oxford Nanoimager (ONI) (refer to https://oni.bio/nanoimager/ for camera, illumination, and objective specifications; this unit has a 532 nm excitation line in place of the standard 561 nm line). The ONI uses a 100 x 1.4NA oil-immersion objective and Z-lock control setting for autofocus. To prevent overheating, two cooling plates were added to the ONI externally, secured with metal clamps, to allow cold water from a water bath to flow through them since the ONI’s built in temperature control system could not maintain imaging temperatures below 25 °C. Before imaging, we set the ONI to the desired temperature and adjust the water bath temperature accordingly after laser activation to stabilize imaging temperature at 25 °C at our ambient temperature of ~22 °C. An illumination angle of approximately 54° was set for TIRF. Samples were excited at 532 nm (at 30% laser power) and 640 nm (at 35% laser power) to capture Cy3 and Cy5 fluorescence emission, respectively, at an optimal signal-to-noise-ratio (S/N). Each FOV was observed for 5 min at a signal integration time of 100 ms per frame unless stated otherwise. Experiments that require colocalization were recorded simultaneously with two laser channels active.

第 34 段问这一段

Fluorescent probe selection & imaging solution Probe design was guided by the requirement for reversible target binding to enable repeated association–dissociation cycles for kinetic fingerprinting. For sequence-specific oligonucleotide probes, we targeted melting temperatures near room temperature (20–25 °C) and used short probe lengths (typically 8–10 nt; 11 nt where noted) to achieve dissociation kinetics on a timescale of ~1 second. Probe GC content was kept ≤50% when possible. At least 2 nucleotides were left unpaired between adjacent FP and CP/tile binding sites to reduce potential stacking interactions that would influence binding kinetics. Probe and tile sequences are provided in Supplementary Table 1. Unless stated otherwise, single-molecule imaging was performed in 2× PBS (pH 7.4; Gibco) supplemented with an oxygen scavenging system consisting of 5 mM 3,4-dihydroxybenzoic acid (Fisher Scientific, AC114891000), 0.05 mg ml⁻¹ protocatechuate 3,4-dioxygenase (Sigma- Aldrich, P8279-25UN), and 1 mM Trolox (Fisher Scientific, 218940050). Where indicated, imaging buffers additionally contain DNA tiles (6 nM each) and/or TX-100 (0.008% v/v; freshly prepared from a 2% stock) and fluorophore-labelled oligonucleotide probes (typically 50 nM).

第 35 段问这一段

For the Nile Red assay, Nile Red was serially diluted in DMSO and then diluted into 2× PBS immediately before imaging to a final concentration of 1 nM. For the RiboGreen assay, imaging buffer contained 2× PBS (pH 7.4), RiboGreen reagent from the Quant-iT™ RiboGreen RNA Assay Kit (0.5% v/v, corresponding to a 1:200 dilution of the supplied reagent stock) and TX-100 (0.008% v/v).

第 36 段问这一段

Capturing strategy & kinetic fingerprinting assay All sample preparation was performed in low-adhesion 1.7 ml microcentrifuge tubes (GeneMate). Unless otherwise noted, all incubations were carried out at room temperature. For surface preparation, each sample well was washed with 100 μl of T50 buffer (10 mM Tris-HCl, 50 mM NaCl, 1 mM EDTA, pH 8.0) for 5 min. After removal of T50, streptavidin (40 μl, 1 mg ml⁻¹) was added and incubated for 10 min. Excess streptavidin was removed and wells were washed three times with 100 μl of 1× PBS.

第 37 段问这一段

For LNP assays, wells were incubated with biotinylated anti-PEG capture antibody (40 μl, 100 nM) for 30 min. Excess antibody was removed and wells were washed three times with 100 μl of 2× PBS. LNP stocks (0.1 μM) were diluted 1,000-fold in 2× PBS to a working concentration of 100 pM (unless otherwise specified) and added to the well. LNP solutions were handled by gentle pipetting and were not vortexed. After a 1h capture incubation, excess LNPs were removed and wells were washed three times with 100 μl of 2× PBS. Imaging solution (100 μl; composition described above) was then added and samples were imaged promptly by TIRF microscopy.

第 38 段问这一段

For bare mRNA assays, wells were pre-incubated with a biotinylated 3′ DNA capture probe (100 μl, 100 nM) for 10 min. Excess capture probe was removed and wells were washed three times with 100 μl of 2× PBS before adding sample. For tiled mRNA experiments, unformulated mRNA was mixed with DNA tiles (final mRNA concentration 10 pM; tile concentration as indicated) and annealed using a thermocycler program of 95 °C for 2 min, 40 °C for 8 min, followed by cooling in a room-temperature water bath for 5 min. The annealed sample was then added to the well and incubated for 1 h to capture tiled mRNA on the surface. Excess mRNA was removed, wells were washed three times with 100 μl of 2× PBS, and 100 μl of imaging solution was added immediately before TIRF imaging (Supplementary Fig. 3).

第 39 段问这一段

Analysis of single-molecule data PINPOINT single-molecule kinetic fingerprinting datasets were analyzed using custom MATLAB scripts to quantify probe-binding kinetics and perform digital counting, following established diffraction-limited kinetic fingerprinting workflows (Supplementary Fig. 4)31,32. Candidate regions of interest (ROIs) were identified by computing an intensity fluctuation map, defined as the average absolute frame-to-frame change in intensity at each pixel across the movie. Local maxima in the fluctuation map were used to seed ROIs, which were defined as 3 × 3-pixel regions centred on each maximum. For each ROI, background-subtracted integrated intensity was computed for every frame to generate an intensity-versus-time trajectory.

第 40 段问这一段

Trajectories were idealized using hidden Markov modelling (HMM) with a custom implementation of vbFRET. Idealized state sequences were used to extract kinetic fingerprint parameters, including ܰ ௕ାௗ (number of binding and dissociation events), 𝜏୭୬,୫ୣୢ and 𝜏୭୤୤,୫ୣୢ (median dwell times in bound and unbound states), and 𝜏୭୤୤,୫ୟ୶ (maximum unbound dwell time). Signal-to-noise ratio (S/N) was calculated as the standard deviation of the fluorescence intensity divided by the mean intensity difference between the bound and unbound states. For each probe modality, thresholds for intensity, S/N and kinetic parameters were optimized using an automated routine within the software to maximize the trajectories classified as accepted (positive detection events) in positive controls while minimizing accepted counts in corresponding negative controls; optimized parameter sets are shown in Supplementary Table 4.

第 41 段问这一段

Colocalization analysis (for sequential or dual-colour assays) was performed in MATLAB using ROI coordinate information retained during movie processing and reconstruction, enabling registration of spots across channels and/or acquisitions and enumeration of colocalized events. Fitting of the cumulative frequency of dwell times Dwell-time distributions were analyzed in MATLAB using cumulative frequency (cumulative distribution) fitting. For each dataset, bound- and unbound-state dwell times extracted from HMMidealized trajectories were pooled and binned at the camera exposure time (100 ms). The cumulative frequency )ݔ(ݕ as a function of dwell time ݔ was then fit with a single-exponential model, ݁݉= )ݔ(ݕ ௫/ఛ, ܿ+ (2) where ݉, 𝜏 and ܿ are fit parameters. For cumulative distributions normalized to span from 1 to 0, ݉ was constrained to −1, ܿ corresponds to the long-time offset, and 𝜏 represents the characteristic (mean) dwell time of the underlying exponential process. Fits were accepted when the sum of squared errors was < 0.05 and ܴ ଶ was > 0.99, indicating that a single-exponential model adequately described the cumulative distribution and that 𝜏 provided a representative dwell-time estimate. Super-resolution analysis (Nile Red)

第 42 段问这一段

Super-resolution LNP images were reconstructed from the fluctuating fluorescence signals arising from repeated, transient association of single Nile Red molecules with hydrophobic LNP domains and/or intrinsic blinking of bound dyes (Fig. 2) according to the PAINT method34. Individual binding events were localized in each frame by least-squares fitting to a 2D Gaussian function, yielding per-event centroid coordinates which were corrected for translational stage drift (generally ≤ 1 pixel) during the measurement using subpixel registration with the discrete Fourier transform cross-correlation method34,35,48. Each localization was then represented as a smaller Gaussian at the centroid coordinates with a standard deviation equal to the average localization error (~30 nm). Gaussian representations for localizations from all frames were then pooled to generate a super-resolution reconstruction for all particles in the field of view, which was used to estimate particle diameter and area (defined by a boundary threshold of ½ maximal localization density within each particle, akin to a full-width at half maximum metric of size), and to compute a circularity index (range 0-1, where 1 = maximum circularity) using the MATLAB regionprops command. The circularity index is equal to ቀ1 − ቁ (3) where ܣ is the area of the bounded region, ܲ is the perimeter of the bounded region, and = ݎ + 0.5. Analyses were restricted to particles containing regions with at least two spatially overlapping localizations (i.e., within localization error of one another) to filter out extraneous/nonspecific events. Size distributions and summary statistics were then compiled across fields of view for comparisons between batches and conditions (Fig. 2 and Supplementary Table 3).

第 43 段问这一段

Burst analysis and Fano factor calculations Bursting in probe-binding trajectories were quantified using a modified Rank Surprise (RS) method adapted from Gourévitch et al44. Interspike intervals (ISIs) were defined as the time between consecutive probe-binding events for each accepted single-molecule trajectory (from HMM-idealized traces). For burst calling, we implemented a global RS approach in MATLAB in which ISIs from all trajectories within an experimental condition were ranked jointly, so that burst identification was not biased by molecules with unusually high or low event counts. The RS algorithm was then used to identify contiguous sequences of short ISIs (“bursts”) and to assign burst start and end points, which were mapped back to each trajectory to preserve single-molecule burst profiles. RS parameters were set to a maximum ISI of 40 s for events to be considered within a burst and an RS cutoff (α) of 3.

第 44 段问这一段

Fano factor analysis was used to test whether spike trains deviated from Poisson statistics. For each condition, the Fano factor was calculated as the variance of spike counts divided by the mean spike count within a time window ܶ. For each trajectory, a window of length ܶ was randomly sampled 100 times (independent random seeds) and Fano factors were averaged across samplings and then across trajectories. Calculations were performed for ܶ = 5,10,20,40 and 60 s (as plotted). Poisson reference behaviour was generated by simulating spike counts using MATLAB’s Poisson random number generator with a mean rate matched to the experimentally observed average burst ISI and using the same number of samplings. The 95% confidence interval for Poisson behaviour was computed using gamma-distribution bounds, gaminv([0.025,0.975], (݊ − 1)/2,2/(݊ − 1)), where ݊ is the sample size.

第 45 段问这一段

mRNA copy number estimation mRNA copy number per LNP was estimated from single-particle RiboGreen fluorescence by normalizing encapsulated-particle intensities to single-mRNA reference23. Bare mRNA1 was imaged under the same optical settings used for LNP measurements to obtain a one-copy intensity reference. The bare-mRNA intensity histogram fitted with a Gaussian model, and the fitted mean was taken as the characteristic intensity of one mRNA copy. Encapsulated mRNA intensity distributions were obtained by imaging RiboGreen-accessible RNA in permeabilized, surfacecaptured LNPs. For each LNP, the estimated copy number was calculated as the particle intensity divided by the one-copy reference intensity, and batch-level copy-number distributions and mean copy numbers were then obtained (Fig. 6b and Supplementary Table 5).

Data availability

第 46 段问这一段

The data supporting the findings of this study are available within this Article and its Supplementary Information. Source data are provided with this paper. Any additional data are available from the corresponding author upon request.

Data availability / Code availability

第 47 段问这一段

The code used in this study has been described in reference31-32 and is available through a DeepBlue repository. Any additional information concerning the code is available from the corresponding author upon request.