Population-level emulation enables fast Bayesian calibration of cardiac digital twins
作者:Clara E Jones, Felix Plappert, Derek J Bivona, Johane H Bracamonte, Zarif Hossain, Isabella Aleman, Lyna Luu, Kenneth C Bilchick, Pim J A Oomen
bioRxiv · 2026年11月11日 · Jones 等 9 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
PURPOSE: Patient-specific cardiac digital twins have the potential to guide individualized therapy, but generating these in a routine clinical workflow remains challenging. This is especially true when the twins must carry quantified uncertainty: Bayesian calibration requires thousands of simulations per patient, and the emulators that reduce this cost are typically trained one patient at a time. We aimed to train a single emulator across a patient cohort, so that a new patient can be calibrated in minutes without new simulations.
METHODS: We trained a population-level Gaussian process emulator whose inputs included a 12-dimensional latent encoding of each patient's clinical features, so that a single emulator represents the whole cohort. We compared spending simulation budgets on resampling the real cohort with augmenting the chort with digital chimeras, synthetic patients interpolated between real patients. Seven parameters of a closed-loop heart and circulation model were calibrated by Markov chain Monte Carlo to ten clinical biomarkers in 26 patients with left bundle branch block, each using an emulator trained without that patient, and the calibrated posteriors were compared against the full simulator.
RESULTS: A single emulator, trained without the held-out patient, calibrated each patient's digital twin in 59.7-63.0 s per patient, versus 15 h with the simulator. Resampling the real cohort was the more efficient training strategy, bringing every output to R 2 ≥ 0 .9, which augmentation did not achieve for the same simulation budget. For held-out patients, both strategies performed comparably (median leave-one-out normalized root-mean-square error 11.0% vs. 10.7%; p =0 .745), and error rose with distance from the cohort centroid (Spearman ρ = +0 .406). The calibrated models showed no cohort-wide bias (median standardized residual - 0 .12between simulator and emulator), and 95% predictive intervals contained 78.5% of targets, with the largest misfit in systolic blood pressure.
CONCLUSION: Removing the need for new simulations for every new patient is a meaningful step toward uncertainty-aware cardiac digital twins that fit within a routine clinical workflow. Because the simulator, surrogate and sampler are interchangeable, the approach used here can be applied to other (cardiac) models and cohorts.