预印本 · 建模 / 计算研究
医疗领域的表格基础人工智能模型:借鉴世界卫生组织的负责任与可信人工智能基准评测
Tabular Foundation AI Models in Healthcare: A WHO-Inspired Benchmark for Responsible AI and Trustworthiness
作者:K. S. Hasan, M. A. A. Borsha, R. J. Ritu, L. Shabbir
medRxiv · 2026年11月24日 · Hasan 等 4 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
Tabular foundation models (TFMs) are increasingly used for structured prediction, yet their suitability for healthcare applications remains uncertain because predictive performance alone does not establish fairness, probabilistic reliability, or robustness. We developed a multidimensional benchmark to compare four TFMs: TabFM, TabPFN, TabDPT, and TabICL, against Logistic Regression and XGBoost across a curated, standardized suite of ten WHO-aligned healthcare classification datasets across diverse disease domains. Additionally, we harmonized clinical schemas, standardized protected sex attributes and outcome targets, and released both balanced-scale and natural-prevalence variants of the datasets to establish a benchmarking resource in healthcare machine learning. All models were evaluated using identical five-fold stratified cross-validation partitions and standardized preprocessing. Performance was assessed using 20 metrics spanning predictive discrimination, sex-based fairness, probability calibration, and robustness to Gaussian feature perturbations. A composite Clinical Model Evaluation Score (CMES) was used to summarize performance across these dimensions. Google TabFM achieved the highest mean CMES (0.8811), followed closely by TabDPT (0.8796), TabICL (0.8775), TabPFN (0.8756), XGBoost (0.8650), and Logistic Regression (0.8549). The Friedman test indicated significant differences among models ({chi}2F (5) = 24.914, p = 1.45 x 10^-4; Kendalls W = 0.498). However, post-hoc comparisons revealed no statistically significant differences among the four TFMs after Holm correction. TFMs generally demonstrated stronger discrimination and probabilistic calibration than conventional baselines, with TabFM achieving the highest mean Area Under the Receiver Operating Characteristic (0.9327) and the lowest expected calibration error (0.0674). Conversely, Logistic Regression exhibited the greatest stability under feature perturbations, while fairness performance varied substantially across datasets and models. These findings highlight the potential of TFMs for small-data healthcare prediction while demonstrating that their advantages are dimension-dependent. Multidimensional, dataset-specific evaluation and external validation remain essential before clinical implementation. All analysis codes, original datasets, and multiple variants of benchmark datasets are publicly available in a GitHub repository to ensure reproducibility and future research.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。