医学伦理研究助手
前沿
论文精读

论文 · 单臂试验

人类感觉运动皮层1500天以上的神经刺激与记录性能

J Neural Eng · 2021年8月13日 · Hughes 等 7 位作者

问这篇
一分钟了解要点一例脊髓损伤者皮层内微刺激1500天后记录与诱发电位仍可用且阈值下降。结果两类电极的记录质量都随时间下降,但刺激电极更能持续记录高幅信号;诱发触觉的检测阈值从第100天中位31.5微安降至第1500天10.4微安。

不需要生物学背景,多打比方

正在获取全文并生成讲解(拿不到全文就依据摘要)…

已等待 0 秒大约需要 10–20 秒

可以先看别的,做好了会自动出现在这里。

这篇还没有动画

动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。

目前只拿到了摘要全文暂时拿不到(可能不是免费全文)。下面是论文摘要。

摘要Abstract

摘要第 1 段问这一段

Objective.Intracortical microstimulation (ICMS) in somatosensory cortex can restore sensation to people with spinal cord injury. However, the recording quality from implanted microelectrodes can degrade over time and limitations in stimulation longevity have been considered a potential barrier to the clinical use of ICMS. Our objective was to evaluate recording stability of intracortical electrodes implanted in the motor and somatosensory cortex of one person. The electrodes in motor cortex had platinum tips and were not stimulated, while the electrodes in somatosensory cortex had sputtered iridium oxide film (SIROF) tips and were stimulated. Additionally, we measured how well ICMS was able to evoke sensations over time.Approach. We implanted microelectrode arrays with SIROF tips in the somatosensory cortex (SIROF-sensory) of a human participant with a cervical spinal cord injury. We regularly stimulated these electrodes to evoke tactile sensations on the hand. Here, we quantify the stability of these electrodes in comparison to non-stimulated platinum electrodes implanted in the motor cortex (platinum-motor) over 1500 days with recorded signal quality and electrode impedances. Additionally, we quantify the stability of ICMS-evoked sensations using detection thresholds.Main results. We found that recording quality, as assessed by the number of electrodes with high-amplitude waveforms (>100µV peak-to-peak), peak-to-peak voltage, noise, and signal-to-noise ratio, decreased over time on SIROF-sensory and platinum-motor electrodes. However, SIROF-sensory electrodes were more likely to continue to record high-amplitude signals than platinum-motor electrodes. Interestingly, the detection thresholds for stimulus-evoked sensations decreased over time from a median of 31.5μA at day 100-10.4μA at day 1500, with the largest changes occurring between day 100 and 500.Significance. These results demonstrate that ICMS in human somatosensory cortex can be provided over long periods of time without deleterious effects on recording or stimulation capabilities. In fact, the sensitivity to stimulation improved over time.

这篇对您:
讲解或动画有问题: