论文 · 建模 / 计算研究
人工智能用于糖尿病视网膜病变筛查:不同人群与成像设备数据集的综合性能比较
Diabetic retinopathy screening using artificial intelligence: a comprehensive performance comparison on datasets from diverse populations and imaging modalities
作者:Philipp Schapotschnikow, Vladyslav Dusiak, Murat Osswald, Paolo S Silva, Leo Anthony Celi, Luis Filipe Nakayama
Physiol Meas · 2026年9月24日 · Schapotschnikow 等 6 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
Objective.Diabetic retinopathy (DR) is the leading cause of preventable blindness in adults and poses significant challenges in low- and middle-income regions due to limited access to skilled clinicians and diagnostic facilities. Automated screening solutions using artificial intelligence (AI) have emerged as an efficient alternative, achieving high diagnostic accuracy. However, these solutions are often developed using data from specific populations obtained using relatively expensive high-end devices. This study addresses the potential scope limitations by evaluating the AI-based screening toolretina.helpacross eight datasets representing diverse populations, imaging modalities, and geographic regions.Approach.The datasets include both public and private sources, with images captured using tabletop and handheld fundus cameras. Key performance metrics for detecting binary referable DR-sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC)-were calculated on an image-by-image basis.Main results.Retina.helpdemonstrated high accuracy on tabletop images, achieving AUROC values of 0.97 on the BRSET and DeepDRiD datasets. Handheld device performance was more variable, with AUROC ranging from 0.88 (Filipino dataset) to 0.99 (Finnish dataset). Sensitivity declined with increased retinal pigmentation, as evidenced by lower values for datasets from Tanzania (62.2%) and Brazil (76.7%) compared to Finland (89.9%). Images from handheld devices often yielded lower sensitivity due to challenges related to low-contrast images. Nonetheless,retina.helpgeneralized well across diverse datasets, showcasing its robustness.Significance.The study highlights the impact of imaging equipment, demographics, and image quality on diagnostic performance. These findings underscore the need for benchmarking AI-based DR screening tools using standardized datasets that encompass diverse populations and imaging conditions. Such evaluations can guide the development of equitable, reliable and robust screening solutions.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。