论文 · 随机对照试验
达芬奇线性电动吻合器 SureForm 在机器人直肠癌保肛手术中的应用价值:一项前瞻性随机临床试验
The application value of Da Vinci linear powered stapler SureForm in robotic sphincter-preserving surgery for rectal cancer: a prospective randomized clinical trial
作者:Shan-Ping Ye, Dong-Ning Liu, Zheng-Rong Li, Yi Cao, Bo Tang, Jin-Yuan Duan, A-Long Luo, Tai-Yuan Li
Surg Endosc · 2026年9月15日 · Ye 等 8 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
BACKGROUND: Anastomotic leakage remains a major complication after robotic low anterior resection for rectal cancer. Technological advancements in stapling devices may influence clinical outcomes. This study aimed to evaluate whether the novel da Vinci SureForm robotic linear stapler reduces anastomotic complications compared with conventional articulating laparoscopic staplers.
METHODS: This single-center, prospective randomized clinical trial was conducted from December 30, 2022, to December 20, 2024. A total of 276 patients with rectal cancer scheduled for robotic sphincter-preserving anterior resection were randomly assigned to undergo rectal transection and anastomosis using either the da Vinci SureForm robotic linear stapler (intervention group) or conventional laparoscopic articulating linear staplers (control group). The primary outcome was the 30-day incidence of anastomotic leakage.
RESULTS: The intervention group had a lower incidence of anastomotic leakage than the control group (6.67 vs. 14.07%, P=0.046), and this trend was also evident for severe cases (Clavien-Dindo grade ≥ II: 1.48 vs. 6.67%, P=0.031). Intention-to-treat analysis suggested a lower leakage rate in the intervention group (6.57 vs. 14.39%, P=0.034). The number of linear stapler cartridges required for rectal transection was lower in the intervention group (1.95±0.67 vs. 2.32±0.85, P<0.001), and the rate of using ≥3 cartridges was also lower (18.50 vs. 37.00%, P<0.001). Multivariate analysis identified stapler cartridges >2 (P=0.002), tumor location (P<0.001), and anastomotic hemorrhage (P=0.013) as independent risk factors for anastomotic leakage.
CONCLUSIONS: The novel da Vinci SureForm linear powered stapler demonstrated a favorable safety profile with a potentially lower incidence of anastomotic leakage and reduced cartridge requirements compared with conventional staplers in robotic sphincter-preserving surgery for rectal cancer.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。