人工智能用于乳腺钼靶筛查的十年:诊断准确性与临床实施的系统综述与荟萃分析(2015—2025年文献)

Diagnostics (Basel) · 2026年9月20日 · Ciurescu 等 5 位作者

问这篇
一分钟了解要点十年证据显示人工智能可作为乳腺筛查的第二读片者或分诊工具,但不能替代放射科医生。结果汇总的独立诊断曲线下面积(衡量区分能力的指标)为0.890,但研究间差异极大;随机试验中人工智能整合读片的癌症检出率比为1.13,未达统计学显著。

不需要生物学背景,多打比方

正在获取全文并生成讲解(拿不到全文就依据摘要)…

已等待 0 秒大约需要 10–20 秒

可以先看别的,做好了会自动出现在这里。

这篇还没有动画

动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。

目前只拿到了摘要全文暂时拿不到(可能不是免费全文)。下面是论文摘要。

摘要Abstract

摘要第 1 段问这一段

Background: Deep-learning artificial intelligence (AI) for mammographic screening moved from proof of concept to randomised evaluation in a single decade. We reviewed and meta-analysed its diagnostic accuracy and its effect on screening programmes, covering the literature published between 2015 and 2025. Methods: PubMed and Europe PMC were searched from 1 January 2015 to 31 December 2025, supplemented by ClinicalTrials.gov and by forward and backward citation searching (PRISMA 2020, PRISMA-DTA, PRISMA-S). Eligible studies evaluated a deep-learning system for cancer detection or triage in a screening population against a histopathological reference standard. Four syntheses were performed: standalone accuracy pooled on the logit-AUC scale (A), a bivariate sensitivity-specificity model (A2), cancer detection rate ratio for AI-integrated versus standard reading (B), and recall rate ratio (C). Random-effects models used restricted maximum likelihood with Knapp-Hartung intervals. Risk of bias was assessed with QUADAS-2 and QUADAS-C, and certainty with GRADE. Results: Twenty-six studies (27 reports, 2019-2025) were included. Pooled standalone AUC across 14 studies and 1,214,885 examinations was 0.890 (95% CI 0.858-0.915), with I2 = 97.4% and a 95% prediction interval of 0.731-0.960. Neither publication year (p = 0.79) nor enriched versus consecutive sampling (p = 0.94) explained this dispersion in meta-regression. The bivariate model (k = 9) gave a summary sensitivity of 73.3% (64.5-80.6) at a specificity of 92.4% (86.8-95.8). Across randomised and paired prospective trials (k = 3), the pooled detection rate ratio was 1.13 (0.83-1.55), with the MASAI randomised trial alone reporting 1.29 (1.09-1.51) and a 44% reduction in screen reading. Non-randomised implementation studies (k = 5), which include a 463,094-women German programme evaluation, pooled to 1.22 (1.08-1.37) with little dispersion (I2 = 19.0%). Recall changed little overall (0.95, 0.81-1.12). Certainty was very low for accuracy outcomes and moderate for the single randomised trial. Conclusions: A decade of evidence supports AI as a second reader and triage tool in organised screening, not as an autonomous replacement for the radiologist. Pooled accuracy is high on average but so dispersed that it cannot be transferred to a new programme; local validation before deployment remains necessary. The larger and more precise detection gains come from non-randomised designs, which is the pattern confounding would produce, so the randomised evidence remains the anchor. Interval-cancer and mortality endpoints are still awaited.

这篇对您:
讲解或动画有问题: