论文 · 综述
人工智能赋能的光电容积脉搏波(PPG)诊断:超越血氧饱和度与心率
Artificial Intelligence Enabled Diagnostics Using Photoplethysmography (PPG): Beyond SpO2 and Heart Rate
作者:Divya Dinesh Joshi, Kaaviyashri Saraboji, Asiya Tasleema Shaik, Krishna Sai Kiran Sakalabaktula, Shreya Purohit, Swathi Godugu, Jasmine Nirmal, Riya Kayarkar, Bernardo Henrique Mendes Correa, Namratha Gangidi, Pratibha Yadav, Jyoti Yadav 等 36 人
Life (Basel) · 2026年9月15日 · Joshi 等 36 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
Photoplethysmography (PPG) is a non-invasive optical technique commonly used to measure heart rate and oxygen saturation, but its waveform contains additional physiological information that can be analyzed using artificial intelligence (AI). This narrative review summarizes the emerging applications of AI-based PPG in cardiovascular, respiratory, sleep, hemodynamic, pregnancy-related, and portal-hypertension assessment, with the aim of evaluating its potential beyond conventional monitoring and identifying barriers to clinical translation. The literature search was conducted using PubMed, Google Scholar, IEEE Xplore, ScienceDirect, and SpringerLink. Additional relevant studies were identified through screening the reference lists of included articles. Studies published between 2002 and 2026 were identified to capture the development of PPG from conventional monitoring to newer AI-based applications. Human studies were prioritized, while relevant computational, simulated, synthetic, ex vivo, and technical studies were also included. Studies unrelated to PPG, duplicates, and studies with limited relevance were excluded. A total of 96 references were included, covering AI approaches such as convolutional and deep neural networks, ensemble methods, transfer learning, U-Net, generative adversarial networks, and Transformer-based models. Overall, the reviewed evidence suggests that AI-based PPG may support blood pressure estimation, atrial fibrillation detection, sleep and respiratory monitoring, vascular aging assessment, pulmonary hypertension screening, preeclampsia assessment, volume-status and compensatory-reserve assessment, and exploratory assessment related to portal hypertension. However, clinical translation remains limited by motion artifacts, sensor and measurement-site variability, skin-pigmentation-related bias, physiological and environmental influences, heterogeneous methods, limited external validation, and inconsistent clinical and regulatory standards.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。