论文 · 队列研究
英国某心胸专科医院 2019—2026 年脓肿分枝杆菌水源性暴发:患者、干预措施及启示
Waterborne outbreak of Mycobacterium abscessus in a UK specialist heart and lung hospital 2019-2026: patients, mitigations and implications
作者:Ellen Heinsbroek, Uta Hill, Olly Allen, Kathy Randall, Caroline Patterson, Iain Roddick, Richard Puleston, Mark Reacher, Neville Q Verlander, Lynsey Emmett, Eleanor Blakey, Fiona Bottrill 等 23 人
Clin Infect Dis · 2026年9月29日 · Heinsbroek 等 23 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
BACKGROUND: Three months after a major cardiothoracic hospital in England relocated to a new building, two cases of Mycobacterium abscessus occurred among lung transplant recipients, triggering an outbreak investigation.
METHODS: Respiratory samples were collected from transplant recipients and patients with Cystic Fibrosis (CF) and non-CF bronchiectasis and tested for Mycobacterium abscessus (other patient groups on clinical request). Environmental sampling was undertaken in between 2019 and 2025. Whole genome sequencing (WGS) was performed on clinical and environmental specimens. An outbreak case was defined as a patient with a positive culture matching the strain from water samples on WGS. Epidemiological investigations included assessment of clinical outcomes; calculation of incidence rates; and a case-control study among transplant recipients.
RESULTS: Between May 2019 and June 2026, 40 outbreak cases occurred in lung transplant recipients (n=11), patients with CF (n=11) and non-CF bronchiectasis (n=14), and other patient groups (n=4), of which 19 were diagnosed with non-tuberculous mycobacterial pulmonary disease. The case-control study found no specific risk factors associated with lung transplant surgery or bronchoscopy. Environmental sampling showed that the outbreak strain had persisted and disseminated throughout the hospital water system. Following extensive control measures, including point-of-use filters and biocide treatment, incidence fell from 12.8 to 2.2 cases per year. No further case has been identified since June 2025, coinciding with a review of enhanced flushing.
CONCLUSIONS: Control measures reduced the incidence of infection but did not eliminate the outbreak strain from the hospital water. Risk mitigation is needed for water systems where vulnerable patients are accommodated.