医学伦理研究助手
前沿
论文精读

论文 · 体外 / 类器官研究

无需离子对试剂的反义寡核苷酸杂质分析合规工作流程

J Pharm Biomed Anal · 2026年9月24日 · Silvia Millán-Martín 等 6 位作者

问这篇
一分钟了解要点开发不含离子对试剂的反义寡核苷酸杂质分析方法,适配质控合规环境。结果方法在pH大于9.5的低浓度醋酸铵条件下获得高灵敏度和干净谱图,金属加合物极少,可在12分钟内完成分析。

不需要生物学背景,多打比方

正在获取全文并生成讲解(拿不到全文就依据摘要)…

已等待 0 秒大约需要 10–20 秒

可以先看别的,做好了会自动出现在这里。

这篇还没有动画

动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。

目前只拿到了摘要全文暂时拿不到(可能不是免费全文)。下面是论文摘要。

摘要Abstract

摘要第 1 段问这一段

In recent years, ion pair-free analytical approaches have gained increasing attention with the aim of mitigating the limitations and drawbacks of ion pair reversed phase chromatography for the characterization of therapeutic oligonucleotides and adherence to green chemistry principles. There is a growing interest in developing ion pair-free strategies in alignment with EU REACH regulation, which prioritize reducing toxic chemical usage, such as volatile or hazardous additives in pharmaceutical or biopharmaceutical analyses. In the case of oligonucleotides, there is a need for sustainable, non-toxic alternatives to conventional reagents like alkylamines and fluorinated alcohols. Therefore, the focus of the present work is to establish an alternative ion pair-free strategy with a special focus on high-throughput analysis and applicability for QC environments using compliance-ready software for data acquisition, data processing and reporting. Method development was performed with pharmaceutically relevant RNA-based single stranded antisense oligonucleotides with different modifications and lengths, that had previously been quantified using an ion pairing method. Chromatographic gradient and MS parameters were optimized for rapid analysis in less than 12 min while maintaining adequate chromatographic resolution where possible, of the full-length product and major impurities. The use of a low ammonium acetate concentration at pH > 9.5 showed high sensitivity with very clean spectra containing minimal metal adduction. Two different quantitation approaches were assessed in the present study for sequence verification and quantitation purposes; one based on untargeted isotopic deconvolution over a wide range of charge states and a new targeted approach using selected extracted ion chromatogram signals for only two most abundant charge states. Although some differences were observed in terms of fractional abundances, resulting values were comparable. Sensitivity of the ion pair-free method showed lower values compared to IPRP-HRMS method, but still within acceptable LODs/LOQs to monitor main impurities during high throughput analysis.

这篇对您:
讲解或动画有问题: