论文 · 队列研究
应用大语言模型从自由文本MRI报告中自动赋予透明细胞可能性评分v2.0:一项可行性研究
Application of large language models for assigning clear cell likelihood score v2.0 from free-text MRI reports: a feasibility study
作者:Yanting Duan, Yilei Zhao, Maowei He, Tiefeng Li, Liuqiong Yang, Zhengyu Hu, Minhong Wang, Zhan Feng
Abdom Radiol (NY) · 2026年10月5日 · Duan 等 8 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
RATIONALE AND OBJECTIVES: To evaluate the performance of four large language models (LLMs) for automated feature extraction and clear cell likelihood score version 2.0 (ccLS v2.0) assignment from free-text reports using a multi-step prompting strategy.
MATERIALS AND METHODS: This retrospective multicenter study included 1,048 magnetic resonance imaging (MRI) reports of renal masses from three institutions (2020-2026). Four LLMs (DeepSeek-V3.2, Qwen 3.5, GPT-5.3, and Gemini 3.0) were evaluated for automated ccLS v2.0 assignment through a three-stage prompting workflow: (1) feature extraction, (2) rule-based criteria matching, and (3) final categorization. Performance was evaluated against expert radiologist consensus-based ccLS v2.0 assignments. Accordingly, these results primarily reflect agreement in task execution rather than diagnostic accuracy for ccRCC.
RESULTS: Gemini 3.0 achieved the highest overall accuracy, correctly assigning ccLS categories in 683 of 802 reports in the internal cohort (85.2%; 95% CI, 82.5%-87.5%) and 211 of 246 reports in the external validation cohort (85.8%; 95% CI, 80.9%-89.6%). All LLMs achieved accuracy greater than 80% for assigning high-risk categories (ccLS 4-5). Gemini 3.0 showed comparatively strong performance in extracting individual imaging features, such as T2-weighted imaging (T2WI) hyperintensity. However, all models showed reduced performance for features requiring multi-step interpretation, particularly the arterial-to-delayed enhancement ratio (ADR), with Qwen 3.5 showing the weakest performance for these complex features. In the pathology subgroup of the internal cohort (n = 237), expert report-based scores yielded an AUC of 0.799 for identifying ccRCC, with LLM-assigned scores showing AUCs of 0.768-0.791 and small AUC differences from the expert standard (-0.031 to -0.008) with overlapping 95% CIs.
CONCLUSION: LLMs employing multi-step prompting, particularly Gemini 3.0, demonstrated favorable performance in assigning ccLS v2.0 categories from free-text reports. Despite limitations in complex feature reasoning, these models showed potential for supporting automated ccLS assessment in radiology workflows; however, in their current implementation, they should be considered decision-support tools that require expert verification rather than autonomous, unsupervised scoring.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。