医学伦理研究助手
前沿
论文精读

论文 · 病例对照

评估大型语言模型(ChatGPT-5)在重症监护中检出潜在药物相互作用:与临床决策支持系统的横断面比较研究

Front Pharmacol · 2026年9月21日 · İlkay Ceylan 等 4 位作者

问这篇
一分钟了解要点在 101 名重症患者中比较 ChatGPT-5 与 UpToDate 的相互作用检出能力。结果ChatGPT-5 检出的数量远高于参照系统(每患者中位数 6 比 0),在 84 名可分析患者中灵敏度 69.8%、特异度 52.4%、总体准确率 65.5%,两系统一致性差(κ 值 0.19)。

不需要生物学背景,多打比方

正在获取全文并生成讲解(拿不到全文就依据摘要)…

已等待 0 秒大约需要 10–20 秒

可以先看别的,做好了会自动出现在这里。

这篇还没有动画

动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。

目前只拿到了摘要全文暂时拿不到(可能不是免费全文)。下面是论文摘要。

摘要Abstract

摘要第 1 段问这一段

BACKGROUND/OBJECTIVES: Polypharmacy in intensive care units (ICUs) substantially increases the risk of potential drug-drug interactions (pDDIs), which may lead to adverse drug events and worsen clinical outcomes. Conventional rule-based clinical decision support systems (CDSSs), although widely used, are limited by static logic and restricted contextual reasoning. Recently, large language models (LLMs) such as ChatGPT have emerged as potential adjunctive tools capable of generating clinically interpretable outputs; however, their diagnostic reliability in safety-critical settings remains unclear.

摘要第 2 段问这一段

METHODS: This cross-sectional study aimed to evaluate the diagnostic performance of ChatGPT-5 in detecting clinically significant pDDIs in ICU patients, using the UpToDate Drug Interaction Checker as the reference comparator. Data were collected from 101 adult ICU patients on a predefined index date. The model referred to as "ChatGPT-5" corresponds to the version available via the OpenAI API in September 2025. A standardized prompt was applied for each patient to ensure consistency. Diagnostic performance metrics, including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), overall accuracy, and Cohen's κ coefficient, were calculated.

摘要第 3 段问这一段

RESULTS: ChatGPT-5 identified a higher number of pDDIs per patient compared with UpToDate (median [IQR]: 6 vs. 0 [0-2]). The mean number of pDDIs per patient was also higher for ChatGPT-5 (7.2 ± 4.1) compared with UpToDate (1.1 ± 1.8). The diagnostic performance analysis was conducted at the patient level. Of the 101 included patients, 17 without a category D or X interaction in the UpToDate reference assessment were excluded from this analysis, leaving 84 patients. Sensitivity, specificity, and overall accuracy were 69.8%, 52.4%, and 65.5%, respectively, with a positive predictive value of 81.5% and negative predictive value of 36.7%. In a conservative full-cohort scenario analysis, treating the 17 excluded patients as discordant cases reduced overall exact agreement from 65.5% (55/84) to 54.5% (55/101). Agreement between the two systems was poor (κ = 0.19), indicating considerable variability in classification.

摘要第 4 段问这一段

CONCLUSION: Although ChatGPT-5 demonstrated limited diagnostic performance and the ability to generate clinically interpretable explanations, its low specificity and limited agreement with a rule-based system highlight important safety concerns. These findings suggest that LLMs may serve as complementary tools rather than standalone solutions in ICU pharmacovigilance. Further multicenter validation studies are required before clinical integration.

这篇对您:
讲解或动画有问题: