TRIDENT:基于内源性光学特性评估左侧结直肠切除术中肠管氧合的在体成像设备——观察性首次人体安全性试验
TRIDENT: inTRaoperative Imaging DEvice based on endogeNous opTical properties to evaluate bowel oxygenation in left-sided colorectal resections. Observational first-in-human pilot safety trial
作者:Alfonso Lapergola, Luca Baratelli, Gabriel Szydlo Shein, Guillaume Philouze, Sylvain Kpekou, Arturo Pardo, Frédéric Triponez, Didier Mutter, Sylvain Gioux, Michele Diana
Surg Endosc · 2026年10月12日 · Lapergola 等 10 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
BACKGROUND: Adequate tissue oxygenation at the anastomotic site is a key determinant of healing after colorectal surgery. Current intraoperative imaging technologies aimed at assessing bowel perfusion present several limitations, including the need for exogenous contrast agents, limited quantification capabilities, or suboptimal integration within the surgical workflow. Single Snapshot Imaging of Optical Properties (SSOP) is a contrast-free optical imaging technology capable of quantifying tissue oxygen saturation (StO2) in real time. This first-in-human observational study aimed to evaluate the intraoperative safety and technical feasibility of SSOP imaging using the Trident system during left-sided colorectal resections.
METHODS: In this prospective, single-center feasibility trial, patients undergoing elective left-sided colorectal resection with primary anastomosis were enrolled. After bowel exteriorization, surgeons identified the intended proximal transection line based on their clinical judgement. SSOP imaging was then performed to quantify tissue oxygenation along the exposed colon segment before resection. The primary endpoints of the study were assessing the overall intraoperative safety and workflow feasibility of the Trident system. The secondary endpoint was to obtain wide-field oxygen saturation (StO2) status images of exteriorized human colon and studying the relationship between oxygen saturation images and a priori surgeon-determined transection lines.
RESULTS: Between September 2023 and April 2024, 10 patients were enrolled (8 males; mean age 65.5 ± 11.8 years; mean BMI 27.5 ± 4.6 kg/m2). SSOP imaging was successfully completed in 9 patients. The mean time required for device positioning and image acquisition was 4.45 ± 0.53 min. Surgeons rated the overall workflow as excellent or good in 100% of cases and no sterility breaches occurred. Quantitative SSOP analysis demonstrated that a priori surgeon-defined transection lines coincided with regions presenting maximal oxygenation in one of the nine cases; in all other cases, transection lines were located well within perfused tissue or proximal to oxygenation transition zones identified by SSOP. No anastomotic leaks were observed.
CONCLUSIONS: This first-in-human study demonstrated that SSOP imaging using Trident is safe, feasible, and compatible with standard surgical workflow during left-sided colorectal resections. The ability to provide real-time, quantitative, contrast-free mapping of bowel oxygenation may represent a promising tool for intraoperative perfusion assessment. Larger prospective studies are needed to evaluate whether SSOP-guided surgery can improve anastomotic outcomes (NCT05973227).