论文 · 建模 / 计算研究
开源大语言模型用于病理脑部磁共振报告分类的比较评价:从提示词到微调模型
Comparative Evaluation of Open-Weight Large Language Models for Pathological Brain MRI Reports Classification: From Prompts to a Fine-Tuned Model
作者:Claudio Demaria, Claudio Crema, Mario Verdicchio, Valentina Brancato, Vincenzo Alfano, Luca Basso, Giuseppe Pontillo, Damiano Archetti, Silvia Fostinelli, Silvia De Francesco, Michela Pievani, Cesare M Baronio 等 17 人
Acad Radiol · 2026年10月14日 · Demaria 等 17 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
RATIONALE AND OBJECTIVES: Automated semantic classification of radiology reports can enhance clinical workflows and research, but often relies on language- and task-specific models, limiting scalability. This study aims to evaluate and improve the 0-shot baseline performance of open-weight large language models (LLMs) in the semantic classification of free-text magnetic resonance imaging (MRI) reports.
MATERIALS AND METHODS: A corpus of 1385 reports from a single neuroradiology center was used to assess four LLMs (GPT-OSS-20B, Magistral-Small-2509, Gemma-4-31B, Qwen3.5-35B-A3B) of comparable scale (∼20-35B parameters). The brain MRI reports were labeled as Pathological or Non-Pathological, with the Pathological ones further classified into five diagnostic categories (Neoformation, Vascular, Inflammation/Infection, Neurodegenerative, Other). The LLMs were evaluated using zero- and few-shot prompting with majority-vote aggregation. Quantized Low-Rank Adaptation (QLoRA) fine-tuning was then applied to the best-performing model across multiple configurations. Performance was assessed using Macro F1, Micro F1, Precision, Recall, and Exact Match Accuracy.
RESULTS: The binary classification task achieved a Macro F1 score of 0.84 on the best-performing Qwen3.5-35B-A3B model, while multilabel classification reached 0.81. Majority voting (MV) outperformed individual-set predictions. QLoRA fine-tuning yielded a Macro F1 score of 0.83 on the multilabel task; the improvement over the 0-shot baseline was statistically supported for Macro F1, Micro F1, Macro Precision, and Exact Match, whose bootstrap 95% confidence intervals excluded zero, but not for Macro Recall. Fine-tuning and few-shot prompting strategies are complementary, with neither consistently outperforming the other. Error analysis showed that the models struggled with borderline annotation cases and often missed secondary labels.
CONCLUSION: Open-weight LLMs demonstrate strong capability for neuroradiology report classification without extensive task-specific training. Fine-tuning further improves performance, supporting integration into scalable semantic radiology data pipelines. However, the present evidence comes from a single Italian center without external validation, and the fine-tuning gain was estimated on a small held-out test set, for which the Macro F1 improvement, though statistically significant, has a confidence interval with a lower bound close to zero. In this light, the approach is best positioned as an internal indexing and semantic-retrieval tool, supporting faster report retrieval, structured cohort identification, internal audit, and scalable phenotyping for neuroradiology research and data warehousing, as well as efficient active-learning strategies, with broader generalizability requiring additional external multicentre validation before clinical deployment.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。