大语言模型生成多内分泌代谢性卵巢综合征饮食方案的营养计算准确性、专家评定临床适当性与安全指标及可重复性:一项基于真实病例的评估

Nutrients · 2026年9月28日 · Ayşenur Çalık 等 5 位作者

问这篇
一分钟了解要点四个大语言模型为多囊卵巢综合征患者生成216份饮食方案,计算误差大且可重复性差。结果没有任何模型在所有营养素上误差都低,Gemini 2.5 Flash 误差最大且平均能量偏差达 +531.1 千卡,多数模型可重复性差。

不需要生物学背景,多打比方

正在获取全文并生成讲解(拿不到全文就依据摘要)…

已等待 0 秒大约需要 10–20 秒

可以先看别的,做好了会自动出现在这里。

这篇还没有动画

动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。

目前只拿到了摘要全文暂时拿不到(可能不是免费全文)。下面是论文摘要。

摘要Abstract

摘要第 1 段问这一段

Background/Objectives: This study evaluated the nutrient calculation accuracy, reproducibility, and expert-rated clinical appropriateness and safety indicators of three-day diet plans generated for women with polycystic ovary syndrome (PCOS), recently proposed to be termed polyendocrine metabolic ovarian syndrome (PMOS). Methods: Anonymized data from six women with heterogeneous PMOS profiles, purposively selected from a single clinic, were converted into standardized Turkish prompts and submitted to ChatGPT-4, Claude Sonnet 4.6, Gemini 2.5 Flash, and Mistral 2.0 through free web interfaces. Three independent generations per case-model combination yielded 216 daily menus. LLM-reported nutrient values were compared with BeBiS 9.0 calculations. Reproducibility was assessed using intraclass correlation coefficients (ICCs). Two experts independently evaluated the first generated plan for each case-model combination using a study-specific clinical appropriateness rubric and red-flag checklist. Results: No model achieved consistently low error across nutrients. Claude Sonnet 4.6 showed the lowest percentage errors for energy, carbohydrate, and fiber; ChatGPT-4 for protein; and Mistral 2.0 for fat. Gemini 2.5 Flash showed the largest percentage errors across all nutrients and a mean energy bias of +531.1 kcal. ChatGPT-4 showed comparatively higher plan-level reproducibility, while the remaining models generally showed poor reproducibility. Claude Sonnet 4.6 had the highest descriptive clinical appropriateness scores and Gemini 2.5 Flash the lowest, but no pairwise differences remained significant after Holm correction. Gemini 2.5 Flash generated the most confirmed study-specific red flags (n = 28), with all six cases meeting the criterion for the "masked low-energy" indicator. Conclusions: LLM-generated diet plans showed model-dependent calculation errors and limited reproducibility, and the present findings do not support their independent or unsupervised use as individualized clinical nutrition recommendations.

这篇对您:
讲解或动画有问题: