医学伦理研究助手
前沿
论文精读

论文 · 综述

人工智能推动生物传感:克服传统局限,迈向智能诊断系统

Biosensors (Basel) · 2026年9月25日 · Vijayaraj 等 5 位作者

问这篇
一分钟了解要点综述人工智能生物传感应以临床可用性而非单纯准确率为评价标准

不需要生物学背景,多打比方

正在获取全文并生成讲解(拿不到全文就依据摘要)…

已等待 0 秒大约需要 10–20 秒

可以先看别的,做好了会自动出现在这里。

这篇还没有动画

动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。

目前只拿到了摘要全文暂时拿不到(可能不是免费全文)。下面是论文摘要。

摘要Abstract

摘要第 1 段问这一段

Artificial intelligence (AI) is increasingly integrated with biosensors to improve signal processing, feature extraction, calibration, and clinical interpretation. However, analytical sensitivity and high internal validation accuracy do not necessarily translate into clinically useful or generalisable diagnostic performance. This review therefore reframes AI-enabled biosensing around clinical actionability rather than technological performance alone. We critically examine how AI can address signal noise, drift, matrix effects, and complex or high-dimensional biosensor outputs while evaluating how model selection should reflect data modality, dataset size, computational constraints, and intended deployment. Importantly, we distinguish the physical limit of detection (LoD) of the sensing system from algorithm-assisted effective detectability: AI cannot intrinsically lower the physical detection limit of a fixed transducer, but it can improve extraction and interpretation of weak signals near the noise floor. A central contribution of this review is a clinically actionable threshold framework that links representative biomarkers to decision-relevant concentration ranges, clarifying when further LoD reduction is clinically meaningful and when robustness, selectivity, dynamic range, calibration stability, and reproducibility matter more. We also critically appraise representative AI-enabled biosensor studies by sample size, validation strategy, reference standard, generalisability, interpretability, computational requirements, and evidence maturity, rather than headline accuracy alone. Across electrochemical, optical and spectroscopic, wearable, and point-of-care platforms, major translational barriers include biofouling, matrix interference, signal drift, dataset shift, insufficient external validation, privacy, and regulatory requirements. We conclude that progress in intelligent biosensing should be judged by reliable performance across clinically relevant ranges and demonstrated utility in real-world diagnostic workflows, rather than by progressively lower LoDs or isolated accuracy values alone.

这篇对您:
讲解或动画有问题: