论文 · 建模 / 计算研究
基于人工智能的药片质量控制:用于自动缺陷检测的视觉数据集与基准
Artificial Intelligence-Based Quality Control of Pharmaceutical Tablets: A Visual Dataset and Benchmark for Automated Defect Detection
作者:Tahir Mahmood, Sabi Ur Rehman, Arslan Niamat, Sung Jae Lee, Kang Ryoung Park
Pharmaceutics · 2026年10月10日 · Mahmood 等 5 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
Background/Objectives: Automated visual inspection of pharmaceutical tablets is increasingly important for detecting manufacturing defects and maintaining consistent product quality. Progress in artificial intelligence-based defect classification is, however, constrained by the scarcity of publicly accessible image datasets covering defective tablets under diverse visual conditions. This study introduces the PharmaVision (PV) dataset, a public visual dataset and benchmark for classifying normal and defective compressed tablets. Methods: The PV dataset contains 640 smartphone-acquired images spanning varied tablet products, backgrounds, and lighting, with fixed tablet-level splits (190/190 training, 30/30 validation, and 100/100 test images for the normal and defective classes, respectively). Twelve representative architectures spanning classical convolutional networks, mobile networks, and vision transformers were benchmarked under an identical protocol using accuracy, precision, recall, and harmonic mean of precision and recall (F1-score), with 95% confidence intervals and paired statistical tests. Cross-dataset generalization was assessed on the independent pillQC dataset without fine-tuning, and efficiency was profiled using parameters, Giga floating-point operations (GFLOPs), latency, and throughput. Results: EfficientNetV2-S achieved the highest F1-score on the PV test set (88.56%), although paired statistical tests did not distinguish it from Xception (87.08%) or Swin-B (85.71%). On pillQC, GoogLeNet and EfficientNetV2-S showed the strongest cross-dataset performance, whereas both vision transformers declined relative to their in-domain results. AlexNet gave the highest theoretical throughput (602.41 frames per second (FPS), median latency 1.66 ms), whereas ShuffleNetV2 and MobileNetV3-small offered the smallest parameter counts. Conclusions: In-domain accuracy, cross-dataset robustness, and measured latency diverged, with no single architecture best on all three axes. The PV dataset, code, and evaluation protocol are publicly available on GitHub to support reproducible AI-based tablet quality control.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。