Accuracy and reproducibility of a large language model in assessing spirometry test acceptability and interpretation: a performance study
作者:Hajed M Al-Otaibi, Husam I Alahmadi, Malik A Althobiani, Kannan Sridharan, Abdullah A Alqarni, Ghazi A Alotaibi
Front Med (Lausanne) · 2026年10月14日 · Al-Otaibi 等 6 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
BACKGROUND: Spirometry is one of the most used pulmonary function tests for assessing respiratory function and diagnosing ventilatory disorders in clinical practice. Evaluation of test validity and interpretation is typically performed by trained healthcare professionals. The present study aims to evaluate the capability of a publicly available large language model (LLM) to perform quality assurance and interpretations of spirometry tests.
METHODS: A total of 150 spirometry tests were retrospectively collected from the pulmonary function laboratories. The spirometry tests were evaluated for acceptability and interpreted by clinicians according to ATS/ERS recommendations as part of standard clinical practice. Subsequently, a publicly available LLM (ChatGPT 5.5) was prompted to evaluate the acceptability and interpret the same spirometry tests according to ATS/ERS criteria. The model interpreted each spirometry test on three separate occasions for assessing reproducibility. Accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV), with 95% confidence intervals (CIs), were calculated by comparing LLM assessments with clinician assessments of spirometry test acceptability and interpretation.
RESULTS: For spirometry acceptability evaluation, ChatGPT demonstrated an overall accuracy of 87% (95% CI: 81%-92%), sensitivity of 91% (95% CI: 85%-95%), specificity of 61% (95% CI 39%-80%), PPV of 94% (95% CI: 89%-97%), and NPV of 48(95% CI: 29%-67%) with Cohen's k of 0.46. The spiromteric interpretation agreement with the clinicians reference standard was moderate, with exact agreement of 0.61 (95% CI: 0.54-0.69) while Cohen's Kappa (Unweighted) was 0.47 (95% CI: 0.37-0.56) and Macro F1 score was 0.39 (95% CI: 0.33-0.49). Reproducibility across three independent trials was moderate (Fleiss' κ 0.58). Class-specific interpretation performance varied by category; sensitivity was highest for normal pattern and restrictive defects (0.72), whereas sensitivity for obstructive defects was 0.27. F1-scores were highest for normal and restrictive defects (0.81 and 0.62, respectively).
CONCLUSION: The current findings suggest that ChatGPT 5.5 has a limited capability, at its current stage of development, to serve as a reliable tool for independent spirometry interpretation in clinical practice. Nevertheless, it may serve as an adjunct to clinical decision-making and educational tools. Prospective controlled studies are needed to confirm these findings.