论文 · 队列研究
人工智能与临床医生对心脏磁共振左心室分割在死亡预测中的表现:一项回顾性、多中心预后研究
Performance of artificial intelligence versus clinician left-ventricular segmentation of cardiac MRI for mortality prediction: a retrospective, multicentre, prognostic study
作者:George Joy, Karan Punjabi, George Searle, Zaid Abdulelah, Tuguldur Gantur, Iain Pierce, George D Thornton, Benjamin Meredith, Hunain Shiwani, Miles Curtis, Shane Cashin, João B Augusto 等 24 人
Lancet Digit Health · 2027年6月16日 · Joy 等 24 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
BACKGROUND: Ejection fraction, a key measure of cardiac function, is used in health care for clinical decision making and risk stratification. We hypothesised that a deep-learning artificial intelligence (AI) segmentation of ejection fraction obtained from cardiac MRI (CMR) outperforms expert clinician segmentation for the prediction of all-cause mortality.
METHODS: In this retrospective, multicentre, prognostic study, we studied a cohort of 27 382 consecutive patients who underwent cardiac MRI (CMR) in the UK and the USA. Patients were referred for CMR from nine hospitals to Barts Heart Centre (BHC), London. Patients were identified from the reporting archive at BHC as having undergone a CMR between Oct 1, 2014 and Dec 31, 2019. A further cohort of patients was also identified from University of Pittsburgh Medical Centre (UPMC), Pittsburgh, PA, USA, as having undergone a CMR between June 1, 2010 and March 31, 2016. Mortality data were obtained from national and local databases. AI segmentation was done on all CMR studies, and Cox proportional hazards models were fitted to compare the prognostic value of AI-measured versus clinician-measured left-ventricular volume metrics. Model fit was compared using the Akaike Information Criterion (AIC), discrimination using C indices and the incremental value of AI over clinician segmentation using likelihood-ratio tests of nested models.
FINDINGS: 27 382 patients received a baseline CMR (26 106 patients from BHC and 1276 from UPMC). The median follow-up was 5·6 years (IQR 4·4-6·9), during which 3458 (13%) of 27 382 patients died. AI ejection fraction showed better model fit (AIC 57 936 vs 58 097, ΔAIC 161 favouring AI) and marginally better discrimination (C index 0·669 vs 0·637; ΔC 0·033 [95% CI 0·026-0·041]). AI ejection fraction significantly improved model fit when added to clinician ejection fraction (χ2=168, p<0·0001), with only slight improvement when clinician ejection fraction was added to AI (χ2=7·5, p=0·023). After adjustment for age and sex, AI-derived ejection fraction showed better model fit (AIC 55 684 vs 55 742; ΔAIC 59) and had marginally better discrimination (C index of 0·781 vs 0·777; ΔC=0·004 [95% CI 0·002-0·006]).
INTERPRETATION: AI-derived ejection fraction shows marginally superior prediction for mortality than clinician-derived ejection fraction in patients who had CMR. Findings support the potential utility of AI for first-line ejection-fraction measurement with clinician oversight, although this should be investigated in prospective studies.
FUNDING: National Institute for Health and Care Research Clinical Lectureship and the British Heart Foundation Accelerator Award.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。