摘要Abstract
Purpose: mRNA vaccines require an effective delivery system for intracellular uptake, and alternative carriers with improved stability and tolerability remain of continued interest. This study evaluated the safety, tolerability, and exploratory immunogenicity of LEM-mR203, an mRNA SARS-CoV-2 receptor binding domain (RBD) booster vaccine formulated with DegradaBALL, a mesoporous silica nanoparticle-based delivery system developed to improve mRNA stability and enable localized delivery.
Methods: In a randomized, double-blind, placebo-controlled, dose-escalation phase 1 study, a single intramuscular dose of LEM-mR203 (40 μg or 100 μg) or placebo was administered to 20 healthy Korean adult volunteers. Safety endpoints included solicited and unsolicited adverse events (AEs), serious AEs, and AEs of special interest. Exploratory immunogenicity comprised anti-RBD antibody concentrations and neutralizing antibody (Nab) titers through Day 366, together with interferon-γ (IFN-γ)/interleukin-4 (IL-4) ELISpot responses.
Results: LEM-mR203 was well tolerated at both dose levels, with mild (Grade 1) injection-site reactions and infrequent solicited systemic AEs; no fever, serious AEs, or AEs of special interest were reported. Transient, asymptomatic decreases in white blood cell count occurred across active and placebo groups and resolved without sequelae. In this pre-immune cohort (85% anti-nucleocapsid reactive), anti-RBD IgG was maintained through Day 366 without a clear booster-induced increase and Nab titers against the Kappa variant (B.1.617.1) waned, consistent with known mRNA vaccine kinetics. Exploratory ELISpot results suggested an IFN-γ-oriented cellular response in the 100 μg group, without evidence of IL-4/Th2 skewing.
Conclusion: A single booster dose of LEM-mR203 was well tolerated, with no major safety concerns over 366 days, and with exploratory cellular responses suggesting an IFN-γ-oriented profile without Th2 skewing. Given the small sample size and high pre-existing immunity, these findings require confirmation in larger, adequately powered studies of DegradaBALL-based mRNA vaccines.
引言Introduction
Coronavirus disease 2019 (COVID-19), caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), evolved into a global health crisis. The continued emergence of variants of concern (VOCs)—spanning the Alpha (B.1.1.7), Beta (B.1.351), Gamma (P.1), Delta (B.1.617.2), and Omicron (B.1.1.529) lineages—has reshaped viral epidemiology and sustained its public health burden., As SARS-CoV-2 has become endemic, vaccine development has shifted from rapid initial protection toward durable immunity sustained by periodic boosting. The safety and tolerability of these boosters are therefore increasingly important, as reactogenicity can affect adherence to repeated vaccination.
Messenger RNA (mRNA) vaccines delivered in ionizable lipid nanoparticles (LNPs) were central to the pandemic response and substantially reduced severe COVID-19. LNPs protect labile mRNA from degradation and mediate efficient intracellular delivery, and they remain the delivery backbone of the authorized mRNA-1273 and BNT162b2 vaccines. Reactogenicity after mRNA vaccination is generally transient and acceptable but remains a consideration for repeated booster dosing, and a range of RNA delivery technologies continues to be explored.
LEM-mR203 uses DegradaBALL, a mesoporous silica nanoparticle delivery system based on an inorganic matrix (Figure 1). DegradaBALL is designed to encapsulate RNA within a porous structure and protect it from RNase-mediated degradation. To date, DegradaBALL has been characterized clinically only with a subcutaneous siRNA product (LEM-S401) developed for a different indication. In preclinical studies of that product, cargo was released over approximately 8 days under simulated physiological conditions, and the nanoparticle-cargo complex was retained at the injection site for at least 5 days in mice, whereas free siRNA was cleared rapidly; in the subsequent first-in-human study, systemic exposure to both the siRNA payload and silicon (the principal constituent of DegradaBALL) was minimal, without dose-dependent absorption., Previous nonclinical and subcutaneous siRNA data suggest possible localized retention and sustained release, but this was not directly assessed after intramuscular LEM-mR203 administration in humans. Localized antigen-retention (“depot”) strategies have been associated with enhanced humoral responses for other vaccine platforms, and local retention with limited systemic exposure could in principle influence the tolerability of a DegradaBALL-based mRNA vaccine; however, these are hypotheses that were not assessed in the present study.
Figure 1. Schematic Representation of LEM-mR203 Structure and Proposed Intramuscular Delivery.
The intramuscular route was selected as it is the predominant route for prophylactic vaccination and consistently induces robust humoral immunity; antigen deposited within the muscle is acquired by antigen-presenting cells recruited to the injection site and conveyed to the draining lymph nodes, where adaptive immune responses are primed. Clinical experience with DegradaBALL has thus far been limited to subcutaneous siRNA delivery, and its application to an intramuscularly administered mRNA vaccine has not previously been evaluated in humans. A SARS-CoV-2 receptor binding domain (RBD) mRNA booster was selected as the first intramuscular application of this platform because the antigen is well characterized, single-dose booster administration is feasible in a pre-immune population, and the extensive safety experience with authorized mRNA vaccines provides a reference frame for interpreting the reactogenicity of a novel carrier. We therefore conducted this first-in-human phase 1 study to evaluate the safety, tolerability, and exploratory immunogenicity of LEM-mR203 following a single intramuscular booster dose in healthy Korean adults, providing initial clinical data for DegradaBALL-based mRNA delivery.
方法Materials and Methods
The study protocol was approved by the Korean Ministry of Food and Drug Safety and the Institutional Review Board of Seoul National University Hospital (Approval number: H-2307-083-1449, ClinicalTrials.gov identifier: NCT06032000). This study was conducted in compliance with the Declaration of Helsinki and the Korean Good Clinical Practice guidelines. Written informed consent was obtained from all participants prior to any procedure related to the study.
Materials and Methods / Study Population
Eligible participants were healthy adult volunteers aged 19–55 years who met one of the following vaccination criteria: (i) completion of a primary COVID-19 vaccination series with a vaccine approved in Korea, with the last dose administered ≥ 90 days (3 months) and < 336 days (48 weeks) before enrollment; or (ii) completion of at least one additional (booster) dose beyond the primary series, with the last dose administered ≥ 120 days (4 months) and < 336 days (48 weeks) before enrollment. Participants had no clinically significant abnormalities in medical history, physical examination, vital signs, 12-lead electrocardiogram (ECG), or clinical laboratory tests.
Participants were excluded if they had significant respiratory symptoms (eg, cough or sore throat) or acute febrile illness (body temperature > 38 °C) within 72 hours before administration of the investigational product, a positive SARS-CoV-2 reverse transcription polymerase chain reaction (RT-PCR) or rapid antigen test at screening, or a diagnosis of COVID-19 within 90 days before enrollment. A detailed list of inclusion and exclusion criteria is provided in Supplementary Information 1.
Materials and Methods / Study Design
This was a phase 1, randomized, double-blind, dose-escalation, placebo-controlled trial. All study visits were conducted on an outpatient basis, and each participant attended 10 visits in total, including screening and the post-study visit (Figure 2). At screening, participants underwent a physical examination including medical history, vital signs, 12-lead ECG, and laboratory tests (hematology, chemistry, coagulation, and urinalysis), and SARS-CoV-2 RT-PCR was performed.
Figure 2. Study design and schedule of the assessments.
The study comprised two sequential dose cohorts. Within each cohort, participants were randomized in an 8:2 ratio to LEM-mR203 or placebo (0.9% normal saline), yielding 8 LEM-mR203 and 2 placebo recipients per cohort (16 LEM-mR203 and 4 placebo recipients overall). The investigational product or placebo was administered intramuscularly into the deltoid muscle of the nondominant arm. Cohort 1 received 40 μg of LEM-mR203 (40 μg of LEM-17219 with 300 μg of DegradaBALL), and Cohort 2 received 100 μg of LEM-mR203 (100 μg of LEM-17219 with 750 μg of DegradaBALL) (Table 1). The ratio of DegradaBALL to mRNA was fixed at 7.5:1 (w/w) across both dose levels, based on formulation development. Each cohort comprised a sentinel group and a remaining group (Figure S1).
Table 1. Dosing Regimens and Composition of LEM-mR203
Given the first-in-human context and the novel mRNA–nanoparticle platform, sentinel participants were monitored for 2 hours and the remaining participants for 30 minutes after administration to assess immediate adverse reactions—longer than the observational period typically applied to authorized vaccines. Within each cohort, the sentinel participants were dosed first; the remaining participants were enrolled, and escalation to the next cohort proceeded, only after an independent Data and Safety Monitoring Board (DSMB) reviewed 7-day safety data and confirmed no significant safety concerns. An interim analysis was performed after Visit 6 (unblinded), after which placebo recipients concluded their follow-up per protocol, whereas LEM-mR203 recipients continued into the extension stage through Day 366. Immunogenicity samples were obtained from all participants, including placebo recipients, at the pre-vaccination (Day 1) and Day 29 time points. However, given the exploratory nature of the immunogenicity objectives and the limited size of the placebo group relative to the LEM-mR203 groups, together with the absence of extended (Day 366) sampling in placebo recipients following unblinding, immunogenicity results are presented for LEM-mR203 recipients. Exploratory immunogenicity endpoints and sampling time points are described below.
Materials and Methods / Randomization and Blinding
Randomization lists were generated by an independent statistician using SAS software (Version 9.4; SAS Institute, Inc., Cary, NC, USA). Within each cohort, the sentinel and remaining groups were randomized independently, at ratios of 2:1 and 6:1 (LEM-mR203 to placebo), respectively. Since LEM-mR203 (suspension) and placebo (saline) differ in appearance, a dedicated unblinded team handled investigational product preparation and administration only; this team was not involved in safety assessments, adverse event evaluation, or data collection. To maintain participant blinding, administration was performed in a curtained area, and participants wore eye masks during the procedure to prevent visual identification of the syringe contents, and interactions between the unblinded team and participants were minimized. All investigators responsible for clinical assessment, laboratory review, and outcome evaluation, as well as other study staff and participants, remained blinded throughout the study.
Materials and Methods / Safety and Reactogenicity
The primary endpoints were the safety and tolerability of LEM-mR203 through Day 29, assessed by solicited adverse events (AEs), unsolicited AEs, serious AEs (SAEs), medically attended AEs (MAAEs), adverse events of special interest (AESIs), and clinical laboratory abnormalities. Exploratory endpoints comprised anti-SARS-CoV-2 RBD IgG concentrations, neutralizing antibody (Nab) titers, and interferon-γ (IFN-γ)/interleukin-4 (IL-4) enzyme-linked immunosorbent spot (ELISpot) responses. Solicited local and systemic AEs occurring within 7 days after vaccination were recorded in participant diaries; all solicited AEs were considered related to vaccination. The causality of all other AEs was assessed by the investigators. Unsolicited AEs occurring within 28 days after vaccination, together with SAEs, MAAEs, and AESIs, were documented in participant diaries and monitored throughout the study.
SAEs were defined as any AE that resulted in death, was life-threatening, required or prolonged hospitalization, or resulted in persistent or significant disability or incapacity. MAAEs were defined as AEs necessitating an unscheduled medical visit or hospitalization. AESIs comprised prespecified immune-mediated, cardiovascular, hematologic, and hypersensitivity-related conditions informed by regulatory guidance (Table S1). Safety assessments included solicited and unsolicited AE reporting, physical examination, vital signs, 12-lead ECG, and clinical laboratory tests; AE severity was graded according to the scale issued by the Ministry of Food and Drug Safety (Tables S2 and S3).
Materials and Methods / Exploratory Immunogenicity Assessment
Humoral and cell-mediated immunogenicity assays were performed at a central laboratory (GCCL Co., Ltd., Yongin, Republic of Korea). Anti-SARS-CoV-2 RBD antibody concentrations were measured using the Elecsys Anti-SARS-CoV-2 S electrochemiluminescence immunoassay (ECLIA; Roche Diagnostics GmbH, Mannheim, Germany) on a cobas e801 module (Roche Diagnostics, Mannheim, Germany). The assay measuring/reportable range was 0.40–25,000 U/mL, and values ≥ 0.80 U/mL were interpreted as positive according to the manufacturer’s instructions and central laboratory procedures. Baseline anti-SARS-CoV-2 nucleocapsid (anti-N) antibody status was assessed using the Elecsys Anti-SARS-CoV-2 immunoassay (Roche Diagnostics GmbH, Mannheim, Germany) on the same analytical platform, with a cutoff index ≥ 1.0 interpreted as reactive.
SARS-CoV-2 Nab titers were measured using a validated live-virus focus reduction neutralization test (FRNT) against the Kappa variant (B.1.617.1) at GCCL. FRNT results were calculated as FRNT50 values and converted to international units per milliliter (IU/mL) using an internal standard, SARS-CoV-2 (Omicron) Neutralizing Antibody Standard (GenScript; Cat. No. A02161; assigned value, 18,642 IU/mL). Serum samples for humoral immunogenicity assessments were collected at Visit 2 (Day 1, pre-vaccination), Visit 6 (Day 29), and Visit 10 (Day 366); anti-N antibody status was assessed at Visit 2 (Day 1) to characterize prior SARS-CoV-2 infection. FRNT results were generated from duplicate measurements, and duplicate FRNT50 values were averaged. Assay precision was considered acceptable when the percent coefficient of variation (%CV) of FRNT50 values was ≤ 50%; samples exceeding this criterion were subject to reanalysis according to the central laboratory’s standard operating procedures.
Cell-mediated immune (CMI) responses were assessed using the Human IFN-γ ELISpotPRO Kit (ALP; Cat. No. 3420–2AST-10; Mabtech) and the Human IL-4 ELISpotPRO Kit (ALP; Cat. No. 3410–2APW-10; Mabtech). Peripheral blood mononuclear cells (PBMCs) were collected at Visit 2 (Day 1), Visit 4 (Day 15), and Visit 6 (Day 29). PBMCs were stimulated with ten SARS-CoV-2 RBD peptide pools manufactured by GenScript, at 200 ng per peptide per well. ELISpot plates were analyzed using a Mabtech Astor ELISpot reader with Mabtech Apex software. IFN-γ and IL-4 responses were reported as spot-forming cells (SFCs) per 10^6 PBMCs after subtraction of the corresponding negative-control background. Each condition was assessed in duplicate wells, and the mean value was used for analysis. No formal participant-level ELISpot positivity threshold was prespecified; assay validity required blank and negative-control spot counts to be less than 10% of the positive-control spot count.
Materials and Methods / Statistical Analysis
Statistical analyses were performed using SAS software (Version 9.4). The safety analysis set included all participants who received LEM-mR203 or placebo. The immunogenicity analysis set comprised all 20 participants with a baseline and ≥ 1 post-baseline sample; results are presented for LEM-mR203 recipients.
No formal sample size calculation was performed; the sample size (8 active and 2 placebo recipients per cohort) was based on regulatory and practical considerations typical of first-in-human studies rather than on statistical power.
All results are descriptive. Adverse events are summarized as the number of events and the number and percentage of participants, with the denominator (n/N) presented alongside percentages given the small group sizes; Clopper-Pearson 95% confidence intervals (CIs) were calculated for solicited local and systemic reactions and unsolicited adverse events. All adverse events were coded using the Medical Dictionary for Regulatory Activities (MedDRA, Version 28.0).
For descriptive summaries and log-scale graphical presentation, values reported below an assay-specific lower reportable or detectable limit were assigned a value equal to half of that limit. Values above the upper reportable range of the anti-RBD antibody assay were handled according to the central laboratory’s dilution and reporting procedures. Missing immunogenicity values were not imputed. For the humoral endpoints (anti-SARS-CoV-2 RBD IgG and SARS-CoV-2 neutralizing antibody titers), values were transformed to the natural-log scale, and the number of participants, mean, standard deviation, median, minimum, maximum, and 95% CI of the mean were calculated; results are presented as the median and interquartile range on the original scale. For the cell-mediated immune endpoints (IFN-γ and IL-4 ELISpot), the number of participants, mean, standard deviation, median, minimum, maximum, and 95% CI of the mean were calculated by dose group and time point. Because this was a small first-in-human study designed to evaluate safety and tolerability, no formal between-group hypothesis testing was prespecified or performed, and no significance threshold was applied. Accordingly, no adjustment for multiple comparisons was required, and no test of data normality was performed. Any numerical differences between dose groups should be interpreted as descriptive only, given the small sample size and limited statistical power.
Results / Study Population
Of 31 volunteers screened, 21 were randomized. One participant assigned to placebo withdrew consent before dosing and was not treated; the remaining 20 received the investigational product or placebo and constituted the safety analysis set. One placebo recipient in the 40 μg cohort subsequently withdrew consent after a post-vaccination COVID-19 diagnosis, and 19 participants completed the study (Figure 3).
Figure 3. CONSORT flow diagram of participant disposition.
Baseline characteristics were balanced across the 40 μg, 100 μg, and placebo groups (Table 2). The mean weight, height, and body mass index (BMI) were 61.9 kg, 166.4 cm, and 22.1 kg/m2 in the 40 μg group; 67.2 kg, 169.7 cm, and 23.0 kg/m2 in the 100 μg group; and 65.6 kg, 166.5 cm, and 23.6 kg/m2 in the placebo group, respectively. At baseline, 17 of 20 participants (85.0%) were reactive to SARS-CoV-2 nucleocapsid antigen (anti-N), and 19 of 20 (95.0%) had received at least one COVID-19 booster dose (Table 2).
Table 2. Baseline Demographic Characteristics
Results / Safety and Reactogenicity
No immediate adverse reactions, SAEs, or AESIs were reported, including no myocarditis, pericarditis, thromboembolic events, or hypersensitivity reactions. Over the study period, AEs were reported in 17 of 20 participants (85.0%): 6 of 8 (75.0%) in the 40 μg group, 7 of 8 (87.5%) in the 100 μg group, and 4 of 4 (100.0%) in the placebo group (Table 3). All AEs were Grade 1 or Grade 2; no Grade 3 or higher AE occurred.
Table 3. Summary of Safety Outcomes Within 28 Days Following Vaccination
Solicited local AEs were reported only in the LEM-mR203 groups and were all Grade 1. Injection-site pain occurred in 3 of 20 participants (15.0%; 1 of 8 [12.5%] at 40 μg and 2 of 8 [25.0%] at 100 μg), and tenderness in 1 of 8 (12.5%) in each dose group (Table 3 and Figure 4). Solicited systemic AEs were infrequent and all Grade 1. In the 40 μg group, diarrhea and fatigue were each reported in 1 of 8 participants (12.5%). In the 100 μg group, myalgia was reported in 2 of 8 (25.0%), and chills, fatigue, dizziness, headache, and cough were each reported in 1 of 8 (12.5%); no solicited systemic AEs were reported in the placebo group (Table 3 and Figure 4).
Figure 4. Percentage of participants reporting (A) solicited local and (B) solicited systemic adverse events within 7 days after vaccination.
Unsolicited AEs were reported in 8 of 20 participants (40.0%): 2 of 8 (25.0%) at 40 μg, 3 of 8 (37.5%) at 100 μg, and 3 of 4 (75.0%) in the placebo group (Table 3). Most unsolicited AEs were Grade 1. The Grade 2 events were dysmenorrhea and oropharyngeal pain in one 40 μg recipient, a rib fracture in one 100 μg recipient, and a post-vaccination COVID-19 diagnosis in one placebo recipient; all resolved by the end of the study.
MAAEs comprised 26 events in 10 of 20 participants (50.0%), with the same proportion of participants affected in each group (4 of 8 [50.0%] at 40 μg, 4 of 8 [50.0%] at 100 μg, and 2 of 4 [50.0%] in the placebo group) (Table 3). Most MAAEs were mild intercurrent events not attributed to the investigational product, with nasopharyngitis being the most frequent. Two MAAEs were Grade 2—a post-vaccination COVID-19 diagnosis (placebo) and a rib fracture (100 μg); the remainder were Grade 1, and the rib fracture was a traumatic injury unrelated to the investigational product.
No clinically relevant findings were observed in physical examination, vital signs, or 12-lead ECG. Clinical laboratory abnormalities were sporadic and Grade 1 across all groups, including placebo (Figure 5). A decreased neutrophil count was reported in 1 participant each in the 40 μg (12.5%) and placebo (25.0%) groups and in 2 participants (25.0%) in the 100 μg group; a decreased white blood cell (WBC) count was reported only in the placebo group (25.0%). Decreased hematocrit and decreased hemoglobin were each reported in 1 participant (12.5%) in the 100 μg group. All laboratory abnormalities were Grade 1 and transient, resolving without sequelae; no Grade 2 or higher laboratory abnormality was reported (Figure 5). Overall, no major safety concerns were detected in this small first-in-human cohort, although the limited sample size precludes the detection of rare adverse events.
Figure 5. Percentage of participants with clinical laboratory abnormalities within 28 days after vaccination.
Results / Exploratory Immunogenicity
Anti-SARS-CoV-2 RBD IgG and Nab titers were assessed at Visit 2 (Day 1, pre-vaccination), Visit 6 (Day 29), and Visit 10 (Day 366) in LEM-mR203 recipients (Figure 6A and B). At baseline, all recipients in both dose groups had detectable anti-RBD antibody concentrations and Nab titers. Anti-RBD antibody concentrations showed little change from Visit 2 to Visit 6 in both dose groups and remained at a similar level through Visit 10; in the 100 μg group, median concentrations at Visit 10 were lower than at baseline (Figure 6A). Nab titers against the Kappa variant (B.1.617.1) were similar between Visit 2 and Visit 6 and were lower at Visit 10 in both dose groups (Figure 6B). Titers did not differ between the 40 μg and 100 μg groups at any time point. Neutralization was assessed only against the Kappa variant, and these results therefore do not reflect neutralizing activity against contemporary SARS-CoV-2 variants.
Figure 6. Exploratory immunogenicity responses following a single booster dose of LEM-mR203.
Cellular responses were assessed by IFN-γ and IL-4 ELISpot at Visit 2 (Day 1), Visit 4 (Day 15), and Visit 6 (Day 29) in LEM-mR203 recipients (Figure 6C and D). In the 100 μg group, median IFN-γ SFC counts increased progressively from Visit 2 to Visit 6, whereas counts in the 40 μg group remained low at all time points (Figure 6C). Responses varied markedly between individuals within each group. IL-4 SFC counts were at or near zero across all time points in both dose groups, and most participants had no detectable IL-4-producing cells (Figure 6D). In light of the high pre-existing immunity of this cohort, these findings are exploratory and do not permit attribution of the observed responses to LEM-mR203 or estimation of the magnitude of a vaccine-induced booster effect.
讨论Discussion
This phase 1 study evaluated the safety, tolerability, and exploratory immunogenicity of LEM-mR203 following a single intramuscular booster dose in healthy Korean adults. In this small first-in-human cohort, LEM-mR203 was generally well tolerated at both the 40 μg and 100 μg dose levels, with solicited reactogenicity limited to Grade 1 events and no serious adverse events, adverse events of special interest, or cases of myocarditis or pericarditis.
LEM-mR203 comprises a chemically modified mRNA encoding the SARS-CoV-2 RBD encapsulated in DegradaBALL, a mesoporous silica nanoparticle-based carrier intended to promote localized retention of its cargo at the injection site (Figure 1). Several nonclinical and prior clinical observations are consistent with this proposed rationale. In a preclinical biodistribution study using fluorescently labeled DegradaBALL (TAMRA) and siRNA cargo (FITC), signals were retained at the intradermal injection site for at least 5 days, whereas free siRNA was undetectable within 24 hours, and in vitro profiling showed sustained cargo release over approximately 8 days under simulated physiological conditions. In a nonclinical study of an mRNA-DegradaBALL vaccine, the platform remained detectable in the injected muscle for approximately 11 days, while levels in other major organs remained below the limit of quantification. In the first-in-human siRNA-DegradaBALL study (LEM-S401), plasma concentrations of the siRNA payload remained below the limit of quantification at all time points after subcutaneous administration, and silicon, the principal structural component of DegradaBALL, showed no dose-dependent systemic exposure. Together, these observations support the biological plausibility that DegradaBALL may promote localized retention of RNA cargo under certain conditions. However, these findings were obtained in nonclinical models or with a different cargo and route, and the present study did not measure biodistribution, injection-site retention, or systemic exposure of the mRNA or DegradaBALL carrier in humans. Accordingly, no conclusions regarding systemic distribution or injection-site retention after intramuscular administration of LEM-mR203 in humans can be drawn, and the available evidence should be regarded as hypothesis-generating.
The intrinsic properties of the carrier material may also relate to the mild systemic reactogenicity observed. Preclinical studies have reported that cargo-free mesoporous silica nanoparticles induce minimal proinflammatory cytokine release (eg, IL-6, IL-12, and IL-1β) from primary immune cells, and in the LEM-S401 study, cytokine panel analysis did not reveal meaningful differences between the treatment and placebo groups. These observations are consistent with a low intrinsic inflammatory potential of the mesoporous silica carrier; however, the LEM-S401 cytokine data were obtained under different conditions (subcutaneous siRNA delivery), and the relative contributions of the carrier material, biodistribution, and other platform-specific factors to the present safety profile cannot be determined.
All solicited AEs were Grade 1, and no fever was reported at any dose level. Solicited systemic events were infrequent: fatigue occurred in 1 of 8 participants (12.5%) in each dose group, myalgia in 2 of 8 (25.0%) in the 100 μg group, and headache in 1 of 8 (12.5%) in the 100 μg group. Direct comparison with authorized mRNA vaccines is limited by the small sample size, the absence of an active comparator, and the highly pre-immune study population.
With respect to laboratory parameters, transient reductions in mean WBC and lymphocyte counts were observed around Visit 3 (Day 8) across groups (Figure 7); such transient changes have been attributed to redistribution of lymphocytes to draining lymphoid tissue during immune priming. As graded laboratory abnormalities, a decreased neutrophil count was recorded in 4 of 20 participants (20.0%) across both active and placebo groups, and a decreased WBC count only in the placebo group; all were Grade 1 and resolved spontaneously. Transient neutropenia is recognized across diverse vaccine platforms and is often attributed to redistribution of neutrophils to the marginated pool rather than suppression of granulopoiesis. The occurrence of these findings in the placebo group suggests they may not be attributable to the investigational product; in the absence of cytokine or neutrophil-subset analyses, these interpretations remain speculative.
Figure 7. Longitudinal profiles of hematologic parameters over time.
The safety profile is consistent with the first-in-human LEM-S401 study, in which adverse events were limited to mild injection-site reactions and systemic exposure was minimal. Although direct comparison is constrained by differences in cargo type, molecular size, route of administration, and population, both studies are consistent with limited systemic exposure and acceptable tolerability across distinct RNA modalities. The present study extends these observations over a follow-up of up to 366 days, during which no delayed safety signals were identified.
In this highly pre-immune population, anti-RBD antibody concentrations were broadly maintained through Day 366 without a marked decline, although in the 100 μg group median concentrations at Day 366 were modestly below baseline, and no pronounced booster (anamnestic) rise was observed. This high baseline immunity was an expected consequence of the eligibility criteria, which required completion of a primary series and, in most participants, at least one prior booster; accordingly, 19 of 20 (95%) participants had received a prior booster and 17 of 20 (85%) were anti-N reactive at baseline. The attenuated booster response is consistent with reports that pre-existing high-titer antibodies blunt the rise after revaccination, a ceiling effect, and this high pre-immune status limits the ability to attribute the observed humoral changes specifically to LEM-mR203. Importantly, this pre-immune profile reflects the population most relevant to current booster vaccination, in whom new boosters must be both tolerable and capable of engaging recall immunity; the maintenance of binding antibody titers and the absence of reactogenicity beyond Grade 1 in this setting are therefore the observations of primary interest. Nab titers were maintained through Day 29 and declined by Day 366, consistent with the waning kinetics described for mRNA vaccine-induced neutralizing antibodies; binding antibody concentrations were better maintained than neutralizing titers, in line with prior observations. For cellular responses, median IFN-γ SFC counts increased progressively from Visit 2 to Visit 6 in the 100 μg group, whereas the 40 μg group remained low, and responses varied markedly between individuals. IL-4 responses remained at or near zero throughout, without evidence of Th2 skewing. The ELISpot findings suggest a possible IFN-γ-oriented response in some 100 μg recipients, but the small sample size and marked inter-individual variability prevent firm dose-response conclusions. Nonetheless, the detection of antigen-specific IFN-γ responses together with undetectable IL-4 is consistent with a Th1-oriented cellular profile and provides a preliminary immunological basis for further evaluation.
As a first-in-human study, this trial was designed to provide an initial assessment of safety and tolerability rather than to test efficacy or immunogenicity hypotheses; the small sample size, single-center design, and absence of an active comparator reflect these early-phase objectives. Accordingly, the study was not powered to detect rare adverse events, dose-response relationships, or between-group immunological differences, and all findings are descriptive. Within these constraints, a consistent Grade 1 safety profile across 20 participants over 366 days of follow-up—with no serious adverse events, adverse events of special interest, or delayed signals—provides a meaningful initial safety characterization to inform subsequent trials. Neutralizing antibodies were assessed only against the Kappa variant (B.1.617.1), reflecting the variant prioritized at the time of study design. As the Kappa variant is no longer circulating, these results do not demonstrate neutralizing activity against contemporary SARS-CoV-2 variants; the neutralization data primarily serve to confirm functional antibody responses rather than to establish variant-specific protection. Cross-neutralization against currently circulating variants was not evaluated and remains an important question for future studies. The discontinuation of placebo follow-up after unblinding at Visit 6 precluded long-term (Day 366) comparisons between LEM-mR203 and placebo. Larger studies with more diverse populations, incorporating safety and immunogenicity endpoints alongside an active comparator, will be needed to confirm these findings and to characterize the benefit-risk profile of DegradaBALL-based mRNA vaccines.
结论Conclusion
A single intramuscular booster dose of LEM-mR203 was generally well tolerated at both 40 μg and 100 μg over 366 days, with reactogenicity limited to Grade 1 events and no serious adverse events or adverse events of special interest. In this highly pre-immune cohort, binding antibody titers were maintained, and exploratory cellular responses showed an IFN-γ-oriented profile without Th2 skewing. Overall, no major safety concerns were detected in this small first-in-human cohort. These findings provide the first clinical safety data for a DegradaBALL-based mRNA vaccine and support its further evaluation in larger, adequately powered studies with active comparators, broader populations, and immunogenicity assays against contemporary variants.