医学伦理研究助手
前沿
论文精读

论文 · 随机对照试验

公共展览中自我引导的β响应式视觉神经反馈:可行性与可用性随机对照试验

JMIR Neurotechnol · 2026年11月3日 · Baumgartner 等 5 位作者

问这篇
一分钟了解要点在公共科学展上测试消费者脑电神经反馈系统的自助使用可行性。结果110名启动者中79人完成有效脑电记录(71.8%),52人进入分析;可用性评分平均72.3分,两组在可用性、放松度和正念状态上无差异。

不需要生物学背景,多打比方

正在获取全文并生成讲解(拿不到全文就依据摘要)…

已等待 0 秒大约需要 10–20 秒

可以先看别的,做好了会自动出现在这里。

这篇还没有动画

动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。

目前只拿到了摘要全文暂时拿不到(可能不是免费全文)。下面是论文摘要。

摘要Abstract

摘要第 1 段问这一段

BACKGROUND: Neurofeedback is studied for stress and anxiety regulation, but most systems require supervision or research-grade equipment. Consumer electroencephalography (EEG) could broaden access, yet autonomous first-contact feasibility, usability, and baseline neural-state effects remain unclear.

摘要第 2 段问这一段

OBJECTIVE: We assessed autonomous completion and usability, tested whether a fixed breathing pacer improved outcomes over visual neurofeedback alone, and explored whether pretask resting beta was associated with usability.

摘要第 3 段问这一段

METHODS: We conducted a single-session, 2-arm randomized feasibility and usability trial at a public science exhibition in Bern, Switzerland, between March and June 2025. Eligible adults were aged 18 years or older, could read German or French, and reported no epilepsy or implanted electronic device. A tablet app guided participants without experimenter assistance through consent, setup, a 30-second eyes-closed baseline, 1:1 randomization, a 120-second beta-responsive task, and questionnaires. The final analytic sample included participants assigned to visual neurofeedback only (VN; n=27) or visual neurofeedback plus a 6 breaths/minute breathing pacer (VN+BP; n=25). Outcomes were usability, relaxation, and state mindfulness. Data were collected prospectively; no secondary data were used. Analyses used Mann-Whitney U, chi-square, Spearman, and permutation tests (2-sided, α=.05); EEG outcome and item analyses were exploratory.

摘要第 4 段问这一段

RESULTS: Of 110 visitors initiating a session, 79 completed the task with a valid EEG recording (71.8%, 95% CI 62.8-79.4) and 52 met analytic criteria (47.3%, 95% CI 38.2%-56.5%). Participants (35 women) had a mean age of 39.0 (SD 11.3) years. Usability was good (System Usability Scale [SUS] mean 72.3, SD 14.7; 95% CI 68.3-76.2), and 31/52 participants scored at least 68 (59.6%, 95% CI 46.1%-71.8%). Usability did not differ between VN and VN+BP (median 75.0, IQR 62.5-81.3 vs median 72.5, IQR 65.0-90.0; Mann-Whitney U=362.5, P=.65; rank-biserial r=-0.07, 95% CI -0.39 to 0.25). Relaxation (median 63.0, IQR 50.0-80.0 vs median 61.0, IQR 50.0-67.0; Mann-Whitney U=276.5, P=.27; r=0.18, 95% CI -0.14 to 0.49) and mindfulness (median 2.4, IQR 2.1-2.8 vs median 2.5, IQR 2.0-3.2; Mann-Whitney U=346.5, P=.68; r=-0.07, 95% CI -0.39 to 0.26) did not differ. Higher resting beta was associated with lower SUS before correction (Spearman ρ=-0.31, 95% CI -0.54 to -0.04; raw P=.03), but not after Benjamini-Hochberg correction (adjusted P=.30). SUS item analyses showed a global pattern (permutation P=.02), strongest for functional integration (ρ=-0.43, 95% CI -0.63 to -0.18; Holm-adjusted P=.01).

摘要第 5 段问这一段

CONCLUSIONS: This trial evaluated an autonomous consumer-EEG neurofeedback system integrating self-fitting, signal-quality checking, baseline calibration, adaptive feedback, randomization, and self-report without operator support. Many first-time users completed the autonomous workflow with acceptable-to-good usability; a fixed, open-loop breathing pacer did not improve usability, relaxation, or state mindfulness; and higher resting beta showed a preliminary association with lower perceived usability. These findings support autonomous consumer-EEG neurofeedback and motivate work on adaptive onboarding, validated EEG pipelines, and objective self-regulation outcomes.