论文 · 队列研究
Lunit人工智能算法在东南亚人群中用于乳腺X线摄影筛查乳腺癌的评估
Evaluation of artificial intelligence algorithms from Lunit for detection of breast cancer with mammogram in a South-East Asian population
作者:Michael Che Hao Seng, Nian-Lin Reena Han, Phua Hwee Tang, Yien Sien Lee
Breast Dis · 2026年11月7日 · Seng 等 4 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
PurposeTo conduct a pre-clinical evaluation of a commercially available artificial intelligence system, Lunit AI, as an independent mammography reader and compare its performance with human readers.Materials and MethodsThis retrospective study analyzed a double-reader population-based mammographic screening cohort of women at an academic women's hospital in Singapore from 2010 to 2017. Lunit AI performance was compared with single-reader (SRR) and double-reader radiologist (DRR) assessment using AUC-ROC, specificity, sensitivity and accuracy.Results1,982 women 35-87 years without breast implants or prior breast cancer were included. The cohort comprised 193 histopathologically confirmed breast cancers, 1,299 healthy controls and 490 histopathologically proven benign recalls. Mean age was 55.7 ± 9.7 years for with cancer and 52.9 ± 8.5 years without cancer.Lunit AI achieved an AUC-ROC of 0.874 (95% CI: 0.843-0.905) compared with 0.811 (95% CI: 0.783-0.840) for SRR assessment and 0.863 (95% CI: 0.846-0.880) for DRR assessment. Compared with SRR, Lunit AI demonstrated higher specificity (81.0% vs 72.6%, p < 0.001), lower sensitivity (80.3% vs 89.6%, p = 0.013) and higher accuracy (80.9% vs 74.3%, p < 0.001). Compared with DRR, Lunit AI demonstrated higher specificity (81.0% vs 72.6%, p < 0.001), lower sensitivity (80.3% vs 100%, p < 0.001) and higher accuracy (80.9% vs 75.3%, p < 0.001). The apparent 100% sensitivity of DRR reflects the retrospective study design and should not be interpreted as true screening sensitivity. Lunit AI detected 156 of 193 cancers and missed 34 cancers of which the majority of the missed cases were 22 cases (64.7%) of microcalcifications.ConclusionLunit AI model shows promising performance in a Southeast Asian population with high AUC-ROC, specificity and accuracy. However it shows lower sensitivity for subtle microcalcifications. These results suggest that Lunit AI may not be suitable as a fully independent reader but as an adjunct to enhance existing clinical workflows in mammographic screening.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。