论文
五种大语言模型从冠状动脉CT血管造影报告中提取CAD-RADS 2.0类别的类别与修饰词准确性评估
Category and Modifier Accuracy in a Five-Model Evaluation of Large Language Model Extraction of CAD-RADS 2.0 from Coronary CT Angiography Reports
作者:Mehrad Rokni, Karis H Yoon, Long Huen Au, Niki H Khaligh, Matthew Moulder, Hannah Prasad, Kamhung Lam, Rahul Iyer, Swetha Ganesan, Stephanie Reshma Warrior, Sarah E McKenney, Misagh Piran 等 13 人
J Imaging Inform Med · 2026年11月10日 · Rokni 等 13 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
This study evaluates large language model (LLM) extraction of Coronary Artery Disease Reporting and Data System (CAD-RADS) categories from coronary CT angiography (CCTA) reports using a guideline-derived specification and examines instruction-related improvement, repeatability, and the limitations of extracting plaque and ischemia modifiers alongside the category. Five LLM platforms (ChatGPT, Claude, Gemini, Grok, and Copilot) processed 400 deidentified CCTA report entries under unprompted, specified, and repeated-specified conditions. The primary outcome was exact category agreement with a report-derived consensus reference under the specification (n = 400). Secondary outcomes included three-component agreement (n = 396), modifier accuracy, instruction-related changes, and repeatability. Inference used report-text cluster bootstrap and paired or permutation tests with Holm adjustment. For the primary outcome, category accuracy under the specification was 92.8-95.5% (371-382/400); secondary outcomes included run-to-run category agreement of 97.5-98.8%, whereas three-component accuracy was 59.3-81.6% (235-323/396). Among assigned references, plaque accuracy was 79.2-94.0% (236-280/298) and ischemia accuracy 45.1-90.3% (79-158/175). The specification improved category accuracy in four of five models and three-component, plaque, and ischemia accuracy in all five. Models did not differ significantly in category accuracy (Cochran Q = 8.73; adjusted p = 0.077) but differed in three-component accuracy (Q = 116.48; adjusted p < 0.001). Category extraction was accurate under the specification, with improvement in most models and high repeatability. Joint evaluation of category, plaque, and ischemia revealed limitations in modifier extraction. External and prospective validation is needed to develop a reliable clinical tool and establish its value in routine practice.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。