论文 · 早期(1 期)试验
新型单轨微导管的首次人体应用:即时测量冠状动脉压力与血流速度
First-in-Human Experience With a Novel Monorail Microcatheter for Instantaneous Coronary Pressure and Flow Velocity Measurements
作者:Alessandro Candreva, Masahiro Hada, Saidamir Djafarov, Gianluca Campo, Divaka Perera, Allen Jeremias, Takuya Mizukami, Bernard De Bruyne, Carlos Collet
JACC Adv · 2026年11月11日 · Candreva 等 9 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
BACKGROUND: Invasive coronary physiology enables comprehensive assessment of epicardial and microvascular disease, but its routine use is limited by technical complexity and prolonged acquisition time.
OBJECTIVES: The PyCath system is a rapid-exchange microcatheter engineered to simultaneously measure intracoronary pressure and thermoconvection-based flow velocity.
METHODS: First-in-human, prospective, single-arm study evaluating the safety and performance of the PyCath system in patients with a clinical indication for coronary physiology assessment. The microcatheter was advanced over a standard coronary guidewire to acquire simultaneous pressure and flow velocity at baseline and during hyperemia. The primary objectives were procedural safety, defined as device-related major adverse cardiac events, and device performance, defined as successful acquisition of pressure and velocity signals. Data were analyzed by an independent core laboratory.
RESULTS: Seventeen patients (mean age 59.3 ± 9.4 years, 76.5% males) referred for invasive coronary physiology assessment were included. Intracoronary pressure and velocity measurements were feasible in 100% and 88% of cases, respectively. The mean time required to obtain both measurements was 70.6 ± 23.6 seconds. The mean fractional flow reserve, coronary flow velocity reserve, and hyperemic microvascular resistance were 0.84 ± 0.12, 2.28 ± 0.79, and 1.46 ± 0.77, respectively. There were no device-related major adverse cardiac events. Test-retest reproducibility was good-to-excellent with intraclass correlation coefficients for fractional flow reserve, coronary flow velocity reserve, and hyperemic microvascular resistance of 0.979 (0.934-0.993), 0.798 (0.477-0.933), and 0.759 (0.397-0.919).
CONCLUSIONS: In this first-in-human experience, the PyCath microcatheter enabled safe and reproducible measurements of intracoronary pressure and flow velocity with excellent reproducibility.