Swaasa®人工智能平台用咳嗽声筛查和辅助诊断呼吸系统疾病的临床验证
Clinical validation of the Swaasa® artificial intelligence platform using cough sounds for screening and aid in diagnosis of respiratory diseases
作者:Balamugesh Thangakunam, Sujith Thomas Chandy, Shubha Deepti Palreddy, Prasanna Samuel P, Devasahayam Jesudas Christopher
Front Med (Lausanne) · 2026年10月28日 · Thangakunam 等 5 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
INTRODUCTION: Cough sound analysis can provide clues to underlying respiratory disease. The Swaasa AI platform, a Software as a Medical Device (SaMD), applies artificial intelligence to cough recordings to generate indications, including overall risk (normal vs. abnormal), spirometric pattern (obstructive, restrictive, or normal), pattern severity (mild, moderate, severe), and the presence of asthma, COPD, ILD, and bronchiectasis.
METHODS: Patients (≥18 years) presenting to our departments with respiratory symptoms were prospectively recruited. Cough sounds were recorded on a mobile device running the Swaasa AI platform, spirometry was performed. Spirometry served as the reference standard for physiological pattern and severity, while physician-established clinical diagnosis served as the reference for disease categories. Polychotomous variables were dichotomized as normal vs. abnormal, & multi-class output for disease condition, pattern severity, and disease categories (asthma, COPD, ILD, bronchiectasis) were defined.
TRIAL REGISTRATION: CTRI/2021/04/032742; registered on 12/04/2021; date of first enrollment: 19/04/2021; trial end date: 14/09/2023.
RESULTS: We recruited 2,179 patients with respiratory diseases and 827 normal individuals; 62% were male. The Swaasa AI platform achieved 90% accuracy in distinguishing normal from abnormal (respiratory condition present) and in classifying normal vs. abnormal spirometry, with descriptive performance subgroup analyses showing broadly comparable performance across age and gender groups For multi-class outcomes, the accuracy ranges were: spirometry pattern: 79%-84%, pattern severity: 76%-84.5%, and disease-type classification: 83%-93%.
CONCLUSION: Swaasa® demonstrates promising performance in distinguishing normal from abnormal respiratory conditions across demographic subgroups, indicating its promise as a screening tool. While the accuracy measures emphasize further refinement to ensure consistent high performance across specific respiratory disease scenarios and severity levels, the study shows its reasonable potential in identifying specific respiratory diseases and their severity.