论文 · 体外 / 类器官研究
建立生物兼容反相高效液相色谱-紫外与超高效液相色谱-蒸发光散射联用方法定量尺寸排阻色谱前后mRNA-脂质纳米颗粒含量
Development of combined bio-RP-HPLC-UV and UHPLC-ELSD methods for quantitation of mRNA-LNP content before and after size-exclusion chromatography
作者:Ting Sun, Qi Wu, Xueli Liu, Zhanlei Xing, Lin Shi, Feizi Hu, Yang Sun, Yafeng Wang
J Chromatogr B Analyt Technol Biomed Life Sci · 2026年11月6日 · Sun 等 8 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
Following the COVID-19 pandemic, mRNA vaccines have been widely deployed, with lipid nanoparticles (LNPs) serving as the prevailing delivery vehicles for mRNA vaccines. Separation and quantitative determination of mRNA and LNP lipid components have therefore attracted considerable attention. Reported mRNA assays suffer from several limitations, including interferences originating from metallic instrument components and complex formulation matrices, insufficient resolution, and prolonged elution durations. Existing analytical approaches for LNP lipid quantification usually involve labor-intensive sample pretreatment and fail to eliminate matrix interferences. Even reported methods capable of simultaneous measurement of nucleic acids and lipids still exhibit deficiencies in resolution and sensitivity. Herein, an integrated analytical platform combining Bio-RP-HPLC-UV and UHPLC-ELSD was established. A biocompatible inert liquid-chromatography system was adopted for mRNA quantification to mitigate adsorption and carry-over effects commonly observed in conventional stainless-steel systems, while chromatographic conditions were optimized to shorten analysis time. A 2/6-port valve-switching splitting device was installed upstream of the UHPLC-ELSD detector to prevent rapid detector contamination induced by direct injection of complex mRNA-LNP formulation matrices and substantially reduce instrument-maintenance frequency. Mobile-phase compositions were further optimized to improve resolution and sensitivity for LNP lipid detection. The validated workflow exhibited favorable precision and excellent linearity (R > 0.9990). The recovery of the mRNA quantification method ranged from 87.89% to 100.31%, and the mean recoveries of the four LNP lipids at three concentration levels varied between 99.52% and 102.46%, guaranteeing assay accuracy. Furthermore, this integrated platform was applied to characterize mRNA-LNP samples before and after size-exclusion-chromatography (SEC) purification. Correlation analysis was performed among mRNA contents, drug-to-lipid ratios, and particle-size data acquired by high-throughput dynamic light scattering (DLS). Results from method-validation experiments and testing of three batches of samples demonstrated that the proposed platform enables simultaneous quantification of mRNA and lipids in mRNA-LNP formulations and multi-attribute parameter correlation verification throughout the SEC purification procedure. Satisfactory inter-batch consistency was achieved across three production batches. This work provides technical support for constructing a facile and practicable quality-evaluation system for mRNA-LNP vaccine formulations.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。