论文 · 队列研究
人工智能增强心电图用于扩张型心肌病的检测与预测
Artificial intelligence-enhanced electrocardiography for detection and prediction of dilated cardiomyopathy
作者:Ewa Sieliwonczyk, Arunashis Sau, Yixiu Liang, Konstantinos Patlatzoglou, Kathryn A McGurk, Libor Pastika, Pantazis Theotokis, Joseph Barker, Boroumand Zeidaabadi, Upasana Tayal, Brian P Halliday, Sanjay Prasad 等 25 人
Eur Heart J · 2026年11月13日 · Sieliwonczyk 等 25 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
BACKGROUND AND AIMS: A major challenge in dilated cardiomyopathy (DCM) care is the identification and management of individuals at risk before disease manifestation. An artificial intelligence (AI) model applied to electrocardiography (ECG) was developed to detect and predict the echocardiographic DCM phenotype (left ventricular dilatation with systolic dysfunction) and was evaluated for its ability to stratify the risk of incident DCM in familial cohorts.
METHODS: A deep learning model was trained to detect the echocardiographic DCM phenotype and to predict its future onset, using more than 330 000 ECG-echocardiogram pairs from the Beth Israel Deaconess Medical Center, Boston. Model performance was validated in cohorts from the UK Biobank, Zhongshan Hospital, and Antwerp University Hospital, and compared with models based on traditional ECG features and echocardiographic traits. To assess performance in familial DCM, genetically predisposed individuals identified through cascade screening at the cardiogenetics clinics of Antwerp University Hospital (n = 166, 18% DCM positive) and Maastricht University Medical Center (n = 177, 18% DCM positive) were evaluated.
RESULTS: The AI-ECG model achieved areas under the receiver operating characteristic curve of .87-.97 for diagnosing the prevalent DCM phenotype, outperforming traditional ECG parameters. AI-ECG was comparable to echocardiography for predicting future DCM (C-index .80-.87 and .80-.90, respectively). In familial cohorts, 5-year negative predictive values were 95.5% (Antwerp) and 91.5% (Maastricht), with corresponding positive predictive values of 42.4% and 39.4%, while high-risk scores were associated with a 5.1-6.4-fold increased risk of incident DCM.
CONCLUSIONS: The explainable AI-ECG model detects the echocardiographic DCM phenotype and predicts future disease, and supports the exclusion of short- to mid-term disease in genetically at-risk individuals. This low-cost tool could help reduce surveillance burden and facilitate earlier intervention.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。