论文 · 单臂试验
Vortex智能结石优化清除(VISOR)系统的评估:首次人体初步研究
Evaluation of the vortex intelligent stone optimized removal (VISOR) system: A first-in-human pilot study
作者:Wenjun Gao, Vineet Gauhar, Li Fang, Jie Gu, Jia-Lun Kwok, Bhaskar K Somani, Yue Cheng, Steffi Kar Kei Yuen, Bohan Wang
Ther Adv Urol · 2026年9月28日 · Gao 等 9 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
BACKGROUND: Despite advancements in suction-assisted flexible ureteroscopy (FURS), Flexible and Navigable Ureteral Access Sheaths (FANS) and Direct-in-scope suction (DISS) techniques face technical hurdles for efficient stone evacuation. The Vortex Intelligent Stone Optimized Removal (VISOR) all-in-one system integrates automatic irrigation-suction and real-time intrarenal pressure (IRP) monitoring. It utilizes a patented reusable 12 Fr flexible ureteroscope featuring a unique dual-channel design, facilitating simultaneous irrigation-aspiration and novel vortex-assisted lithotripsy.
OBJECTIVES: To evaluate the feasibility, safety and preliminary efficacy of the VISOR system for the treatment of upper urinary tract stones in a first-in-human pilot study.
DESIGN: Prospective, single-arm, single-center, first-in-human pilot study.
METHODS: Twenty patients with upper urinary tract stones (median maximum diameter 20 mm; median stone volume 1666 mm3) underwent VISOR system between July and September 2025. The primary outcome was the 24-hour stone-free rate (SFR; residual fragment ≤2 mm) by low-dose non-contrast computed tomography. Secondary outcomes included stone clearance rate, 4-week SFR, operative time, IRP control, laser efficacy, complications (Clavien-Dindo system), and Wisconsin Stone Quality of Life (WISQOL) score.
RESULTS: The 24-hour and 4-week SFR were both 90% (18/20; 95% CI: 68.3%-98.8%). Median operative time was 29 minutes (IQR: 24-36), median IRP was 20 mmHg (IQR: 18-21), and median laser efficacy was 50 mm3/min (IQR: 25-75). WISQOL score improved by a median of 20 points. No Clavien-Dindo Grade I-IV complications occurred.
CONCLUSION: This first-in-human pilot study provides preliminary evidence supporting the feasibility and safety of the VISOR system in selected patients with upper urinary tract stones. The system consolidates pressure monitoring, automated suction, and vortex-assisted lithotripsy into a single platform, which may simplify surgical workflow. While results are promising, larger randomized controlled trials are necessary to validate these preliminary findings.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。