论文 · 队列研究
医学影像与儿童及青少年脑肿瘤风险
Medical Imaging and Pediatric and Adolescent Brain Tumor Risk
作者:Diana L Miglioretti, Susan A Alber, Marilyn L Kwan, Priscila Pequeno, Erin J A Bowles, Robert T Greenlee, Natasha K Stout, Sheila Weinmann, Malini Mahendra, Melanie Francisco, Lisa M Moy, Carly Stewart 等 16 人
JAMA · 2026年11月19日 · Miglioretti 等 16 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
IMPORTANCE: Ionizing radiation from medical imaging may increase brain tumor risk.
OBJECTIVE: To quantify brain tumor risk associated with radiation exposure from medical imaging in children and adolescents.
DESIGN, SETTING, AND PARTICIPANTS: Retrospective cohort study of children born from 1996 through 2016 who were enrolled from birth in 6 US health care systems or Ontario, Canada, and were alive and cancer-free at age 2 years, with follow-up through December 31, 2017 (US sites), and December 31, 2024 (Ontario).
EXPOSURES: Cumulative radiation dose to the brain from medical imaging, lagged by 2 years.
MAIN OUTCOMES AND MEASURES: Incident brain or other central nervous system tumors. Hazard ratios (HRs) were estimated using Cox proportional hazards models for categorical dose, and excess relative risks (ERRs) were estimated using linear dose-response models for continuous dose.
RESULTS: Among 3 704 860 children (1 900 285 [51.3%] male) followed up for 45 671 641 person-years (mean follow-up, 12.3 years), 1536 brain tumors were diagnosed. Mean radiation dose from 1 head computed tomography (CT) examination was 66.2 mGy (SD, 22.2). Among children with cumulative dose of 1 mGy or greater, mean cumulative dose was 73 mGy (SD, 95) overall and 100 mGy (SD, 105) among those diagnosed with brain tumors. Compared with no exposure, brain tumor risk increased with cumulative dose (>0 to <1 mGy: HR, 1.12 [95% CI, 1.01-1.26]; 1 to <5 mGy: HR, 1.71 [95% CI, 0.88-2.96]; 5 to <50 mGy: HR, 1.86 [95% CI, 1.16-2.81]; 50 to <75 mGy: HR, 2.30 [95% CI, 1.64-3.12]; 75 to <100 mGy: HR, 2.02 [95% CI, 1.13-3.30]; 100 to <150 mGy: HR, 2.81 [95% CI, 1.53-4.66]; ≥150 mGy: HR, 3.85 [95% CI, 2.43-5.75]). Cumulative dose was associated with brain tumor risk overall (ERR per 100 mGy, 1.27 [95% CI, 0.83-1.77]; P < .001), with stronger associations for aggressive histologies (ERR per 100 mGy, 1.51 [95% CI, 1.00-2.11]; P < .001). By age 21 years, exposure comparable to 1 head CT was associated with 7.9 excess brain tumors per 10 000 children, or approximately 1 excess tumor per 1266 head CT examinations. The estimated population-attributable fraction was 10.1% (95% CI, 5.8%-14.2%).
CONCLUSIONS AND RELEVANCE: Medical imaging in children and adolescents was associated with a dose-related increase in brain tumor risk. These findings support careful clinical justification and dose minimization when pediatric imaging using ionizing radiation is indicated.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。