论文 · 队列研究
使用大型语言模型识别并提取腹盆部CT报告中的进一步影像检查建议及可执行细节
Use of a large language model for identification and extraction of actionable details from recommendations for additional imaging in abdominopelvic CT reports
作者:Robert A Frank, Andrew Carney, Amirkasra Mojtahed, Ramin Khorasani, Kristine S Burk, Ronilda Lacson
Abdom Radiol (NY) · 2026年11月24日 · Frank 等 6 位作者
不需要生物学背景,多打比方
正在获取全文并生成讲解(拿不到全文就依据摘要)…
已等待 0 秒大约需要 10–20 秒
可以先看别的,做好了会自动出现在这里。
这篇还没有动画
动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。
摘要Abstract
OBJECTIVE: Automated identification and extraction of recommendations for additional imaging (RAI) from radiology reports could facilitate closed-loop tracking and follow-up completion. We compare a prompt-engineered GPT-4.1 large language model (LLM) versus a validated encoder-only transformer deep learning model (bidirectional encoder representations from transformers [BERT]) for detection of RAI in abdominopelvic computed tomography (CTAP) reports, and evaluate GPT-4.1 for extraction of actionable RAI elements.
METHODS: This retrospective study included CTAP reports from a multi-institution system in 2023. LLM and BERT were used to identify RAI from radiology reports; LLM also extracted RAI actionable elements (modality, body part, time frame, rationale). Recall, precision, F1, and accuracy for RAI detection were determined using human-annotated reference standard. Paired comparison between each model's accuracy used McNemar's test. LLM recall, precision, F1, and accuracy for actionable element extraction were computed. Element prevalence was compared using chi-square test.
RESULTS: 2000 random reports for unique patients (58% women; mean age 58.5 ± 17.5) included 215 RAI within 206 reports. For RAI detection, GPT-4.1 recall, precision, F1 and accuracy were 95.6%, 98.5%, 97.0% and 99.4%, respectively; BERT recall, precision, F1 and accuracy were 93.7%, 96.5%, 95.1% and 99.0% (p = 0.16). Recommendation element recall were as follows: 100.0% for time frame, 93.9% for body part, 90.2% for rationale, and 94.2% for modality. Precision were 100.0%, 95.7%, 94.6% and 86.1%, respectively. 29/215 (13.5%) RAI were complete (specified all actionable elements). Prevalence of actionable elements varied (p < 0.001), highest for rationale (215/215, 100%), followed by body part (213/215, 99.1%), modality (191/215, 88.8%), and time frame (31/215, 14.4%).
CONCLUSION: GPT-4.1 demonstrated high accuracy for extraction of RAI and enabled accurate extraction of actionable elements. LLM integration into radiology workflows can facilitate automatic closed-loop communication and tracking of recommended imaging, which may reduce diagnostic delays.
还没有查过关联研究
我会去找这篇研究之前的基础工作、做类似事情的研究,以及之后引用它的研究,并说明每篇为什么相关。