医学伦理研究助手
前沿
论文精读

论文

评估前沿大语言模型在消化内科 AI 辅助鉴别诊断中的表现:诊断性能与重复运行一致性的比较研究

Bioengineering (Basel) · 2026年10月23日 · Ji 等 6 位作者

问这篇
一分钟了解要点用 50 例消化科疑难病例比较四个前沿大语言模型的诊断准确性与稳定性。结果Gemini 2.5 Pro 的首选诊断序次评分显著高于其他三个模型,完全匹配率为 46%,而 GPT-5 为 22%,GPT-4.1 和 DeepSeek-V3.1 各为 18%。

不需要生物学背景,多打比方

正在获取全文并生成讲解(拿不到全文就依据摘要)…

已等待 0 秒大约需要 10–20 秒

可以先看别的,做好了会自动出现在这里。

这篇还没有动画

动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。

目前只拿到了摘要全文暂时拿不到(可能不是免费全文)。下面是论文摘要。

摘要Abstract

摘要第 1 段问这一段

BACKGROUND: Large language models (LLMs) have shown potential for clinical decision support. However, the diagnostic performance of newly released frontier models-including GPT-5 and Gemini 2.5 Pro-in gastroenterology remains insufficiently evaluated. This study evaluated the diagnostic performance and repeated-run consistency of four frontier LLMs-DeepSeek-V3.1, GPT-5, GPT-4.1, and Gemini 2.5 Pro-in challenging gastroenterology cases.

摘要第 2 段问这一段

METHODS: This cross-sectional comparative study evaluated four LLMs (DeepSeek-V3.1, GPT-5, GPT-4.1, and Gemini 2.5 Pro) using 50 challenging gastroenterology cases retrieved from PubMed. Cases published after February 2025 were selected to minimize the potential risk of training-data contamination and prior model exposure. Each case was structured into a standardized prompt comprising clinical history, examination findings, laboratory results, and imaging data. Three independent runs were performed for each case. First-run outputs were used to assess ordinal primary diagnostic scores and differential-diagnosis quality, whereas all three runs were used to assess repeated-run consistency. Outputs were anonymized and scored by a gastroenterologist blinded to model identity.

摘要第 3 段问这一段

RESULTS: Gemini 2.5 Pro achieved significantly higher ordinal primary diagnostic scores than the other three models (all Holm-adjusted pairwise p < 0.01). Exact-match rates were 46% for Gemini 2.5 Pro, 22% for GPT-5, and 18% each for GPT-4.1 and DeepSeek-V3.1. All four models had a median differential-diagnosis quality score of 4; the Friedman test did not detect a statistically significant difference among the models (p = 0.725). Complete agreement in the primary diagnosis across all three runs was observed in 68-78% of cases, depending on the model. No statistically significant differences in repeated-run consistency scores were detected among the models.

摘要第 4 段问这一段

CONCLUSIONS: In this investigator-selected benchmark of 50 published gastroenterology cases, Gemini 2.5 Pro achieved higher ordinal primary diagnostic scores than the other three models. No statistically significant differences were detected in differential-diagnosis quality or repeated-run consistency. These nonsignificant findings do not establish equivalence. Prospective evaluation in clinical settings is required before drawing conclusions about clinical effectiveness.

这篇对您:
讲解或动画有问题: