常规方法与人工智能辅助系统在糖尿病前期及糖尿病患者视网膜病变筛查中的比较:单中心前瞻性分析

Medicina (Kaunas) · 2026年11月18日 · Arici 等 13 位作者

问这篇
一分钟了解要点在真实内科人群中比较人工智能视网膜筛查与眼科检查的一致性结果人工智能系统敏感性约70%–75%、特异性约76%–84%,阴性预测值高(93%–94%)但阳性预测值低(41%–43%),并系统性地过度报告病变;在糖尿病前期人群中几乎没有一致性,对OCT诊断的黄斑水肿敏感性仅45.5%。

不需要生物学背景,多打比方

正在获取全文并生成讲解(拿不到全文就依据摘要)…

已等待 0 秒大约需要 10–20 秒

可以先看别的,做好了会自动出现在这里。

这篇还没有动画

动画会把研究的流程、作用机制和关键结果一步一步演示出来,每一步都标明出自原文哪里。制作大约需要一两分钟。

目前只拿到了摘要全文暂时拿不到(可能不是免费全文)。下面是论文摘要。

摘要Abstract

摘要第 1 段问这一段

Background and Objectives: AI-assisted retinal imaging is increasingly proposed to expand diabetic retinopathy (DR) screening capacity, but most validation studies use reading-center standards, exclude prediabetes, and assess macular edema against photographic surrogates rather than optical coherence tomography (OCT). We compared an AI-assisted retinal screening system with routine ophthalmological examination in an unselected internal medicine screening population. Materials and Methods: In this prospective, cross-sectional diagnostic accuracy study, consecutive adults with prediabetes or diabetes underwent AI-assisted retinal imaging (index test) followed by masked ophthalmological examination (reference standard), with OCT as the reference for macular edema. Analyses were performed at the eye level (n = 714) and patient level (n = 357) using Wilson score 95% confidence intervals and Cohen kappa (κ) for agreement. Results: Among 357 patients (714 eyes; 83.8% diabetes, 16.2% prediabetes), DR prevalence by ophthalmological examination was 15.0% (eyes) and 17.9% (patients), versus 24.4% and 33.1% by AI (McNemar p < 0.001). Eye-level and patient-level sensitivity and specificity were 70.1% and 83.7% and 75.0% and 76.1%, respectively. Negative predictive value was high (93-94%) but positive predictive value was low (41-43%); agreement was moderate at the eye level and fair at the patient level (κ = 0.428 and 0.384, respectively). False-positive AI calls were associated with higher HbA1c and albuminuria (adjusted odds ratio for log-transformed ACR 1.23, p = 0.040); false negatives had milder disease. In prediabetes, DR prevalence was 1.7% and agreement was absent (κ = -0.03). AI sensitivity for OCT-defined macular edema was 45.5% (κ = 0.197), with no significant central macular thickness difference by AI status. Conclusions: The AI system showed high negative predictive value but systematically over-called DR, with only fair-to-moderate agreement and performance below accepted screening benchmarks, particularly in prediabetes and for macular edema. These findings support its use as a rule-out triage adjunct with ophthalmological confirmation of positive results, rather than an autonomous substitute, and argue for local recalibration before deployment.

这篇对您:
讲解或动画有问题: