预印本 · 病例报告
GC801 辅助的 AAV 基因治疗用于一名庞贝病新生儿
GC801-enabled AAV gene therapy in a neonate with Pompe disease
作者:J. Chen, W. Ma, H. Qi, X. Ma, Y. He, L. He, Y. Ke, L. Zhuang, X. Jiang, J. Wang, J. Xu, Y. Xia 等 17 人
medRxiv · 2026年9月29日 · Chen 等 17 位作者
不需要生物学背景,多打比方
讲解6 部分
依据论文全文。
这项研究的主要目的,是评估GC801作为新生儿基因治疗前"脱敏"手段(即先清除体内妨碍治疗的抗体)的安全性和有效性。
“the primary objective was to evaluate the safety and efficacy of GC801 as a desensitization platform for neonatal gene therapy”
研究设计要评估的是:GC801能否清除体内原有的抗AAV9抗体,用于那些本来因为存在这类抗体而不能接受AAV基因治疗的儿童患者,并考察其安全性和初步疗效。
“was designed to evaluate the safety and preliminary efficacy of GC801 for the depletion of pre-existing anti–AAV9 antibodies in pediatric patients who were otherwise ineligible for AAV-mediated gene therapy”
研究原计划招募三名0到8岁的患者,本篇报告介绍的是第一例"哨兵病例"——一名患有婴儿型庞贝病、且体内已存在抗AAV9免疫力的新生儿。
“We planned to enroll three patients aged 0 to 8 years; the present report describes the sentinel case—a neonate with IOPD and pre-existing anti-AAV9 immunity”
符合入选条件的患者,需在筛查时抗AAV9结合抗体滴度在1:1000到1:10000(含两端)之间,且IgG水平在该年龄段的正常范围内。
“Eligible participants were required to have serum anti-AAV9 binding antibody titers ranging from 1:1000 to 1:10,000 (inclusive), with IgG levels within the normal age-adjusted range at screening”
主要的排除条件包括:本人或家族有原发性或继发性免疫缺陷史、对链球菌或蛋白酶来源制剂过敏、有严重过敏反应或过敏性休克史、入组前4周内有明显合并疾病、入组前2周内接种过疫苗,或研究者认为不适合参加的其他情况。
“Key exclusion criteria included a history or family history of primary or secondary immunodeficiency, hypersensitivity to streptococcal or protease-derived agents, severe allergic reactions or anaphylaxis, significant intercurrent illness within 4 weeks before enrollment, vaccination within 2 weeks before enrollment, or any other condition deemed unsuitable by the investigator”
GC801是一种来源于化脓性链球菌IdeS的半胱氨酸蛋白酶变体,由北京Genecradle公司开发,按0.2 mg/kg的剂量单次静脉输注给药。
“GC801, a cysteine protease variant derived from Streptococcus pyogenes IdeS and developed by Beijing Genecradle Therapeutics,1 was administered as a single intravenous infusion at a dose of 0.2 mg/kg”
如果用药后血清总IgG下降到低于基线的50%,这名患者就继续接受GC301治疗。
“if total serum IgG decreased to less than 50% of baseline values, the patient proceeded to receive the GC301”
先用单剂量的IgG降解酶GC801(0.2 mg/kg)做预处理,安全地把血清IgG在5天内从6.25 g/L降到最低点0.72 g/L。
“Preconditioning with a single dose of the IgG-degrading enzyme GC801 (0.2 mg/kg) safely reduced serum IgG from 6.25 g/L to a nadir of 0.72 g/L within 5 days”
这段"药理窗口期"使GC301载体得以成功转导,推动GAA活性到第84天大幅升高至19.38 mmol/L/16h。
“This pharmacological window facilitated successful GC301 vector transduction, driving a robust increase in GAA activity to 19.38 mmol/L/16h by day 84”
关键的是,除庞贝病本身的表现之外,没有观察到不良事件。
“Crucially, no adverse events beyond the underlying IOPD were observed”
没有观察到可归因于GC801的不良事件。
“No AEs attributable to GC801 were observed (Table 1)”
GC801的血药浓度在输注后3小时达到峰值0.37 μg/mL,50小时时仍高于0.25 μg/mL,到大约第14天降至检测下限以下。
“GC801 concentrations peaked at 0.37 μg/mL 3 hours post-infusion, remained above 0.25 μg/mL at 50 hours, and declined to the lower limit of detection (LoD) by approximately day 14”
血清IgG基线为6.25 g/L;输注GC801后,24小时和48小时分别降至2.41 g/L和1.82 g/L(48小时前后正好是给GC301的时间);到GC801后第5天,IgG进一步降到0.72 g/L。
“Serum IgG was 6.25 g/L at baseline. Following GC801 infusion, levels decreased to 2.41 g/L and 1.82 g/L at 24 and 48 hours, respectively (coinciding with GC301 administration at ~48 hours). By day 5 post-GC801, IgG further declined to 0.72 g/L”
GAA活性从GC301输注后第28天的9.67 mmol/L/16h升高到第84天的19.38 mmol/L/16h。
“GAA activity increased from 9.67 mmol/L/16 h on day 28 to 19.38 mmol/L/16 h on day 84 post-GC301 infusion”
这说明用GC801做预处理并没有明显改变身体新产生的抗体反应。
“This indicates that GC801 conditioning did not substantially alter de novo antibody responses”
与庞贝病本身有关的疗效指标(例如运动发育里程碑或生存)不在本次分析范围之内。
“disease-specific outcomes (e.g., motor milestones or survival) fall outside the scope of this analysis”
还需要今后的研究来确定最佳的给药时间窗,以及该策略能否适用于其他类型的AAV载体。
“Future studies are warranted to define optimal dosing windows and applicability across diverse AAV serotypes”
研究方案获得了中国人民解放军总医院伦理委员会的批准(批准号S2025-100-02和S2026-036-02),并按照《赫尔辛基宣言》执行。
“The study protocol was approved by the Ethics Committee of the Chinese PLA General Hospital (approval number S2025-100-02 and S2026-036-02) and conducted in accordance with the Declaration of Helsinki”
入组前已取得受试者法定监护人的书面知情同意。
“Written informed consent was obtained from the legal guardians of participant prior to enrollment”
研究设计由五名学术机构研究者和四名Genecradle公司代表共同完成。
“Study design was collaborative between five academic investigators and four representatives from Genecradle Therapeutics”
数据收集和分析由研究者和公司代表共同进行;但Genecradle公司没有进一步参与数据解读或论文撰写。
“Data collection and analysis were performed jointly by the investigators and company representatives; however, Genecradle Therapeutics had no further role in data interpretation or manuscript preparation”
所有作者都可以完全访问研究数据,并保证数据的准确完整以及研究严格按方案执行。
“All authors had full access to the study data and vouch for the accuracy and completeness of the data and the fidelity of the study to the protocol”
这是一项单臂、开放标签的首次新生儿用药探索,受试者是无法接受常规AAV基因治疗的患儿;对这类没有其他可选疗法的脆弱人群,需要特别关注风险与获益的权衡,建议核实方案中是否预设了出现严重不良事件时的停药和抢救规则。AI 分析
受试者是0至8岁的儿童,且本报告中的是新生儿,属于无法自行同意的脆弱群体;原文写明由法定监护人签署书面知情同意,审查时建议核实同意书是否用监护人能理解的语言说明了这是一项首次用于新生儿的探索性治疗、其未知风险以及替代方案。AI 分析
原文写明研究方案经中国人民解放军总医院伦理委员会批准,并遵循《赫尔辛基宣言》,同时在中国临床试验注册中心注册;建议核实注册信息与伦理批件、实际执行方案(包括入排标准、随访时间)是否一致,以及有无数据安全监查委员会对这类高风险首次人体应用进行独立监查。AI 分析
研究设计由五名学术研究者与四名企业代表共同完成,数据收集与分析由研究者和企业代表共同进行,但原文写明企业在数据解读和稿件撰写上没有进一步角色,且所有作者均可完整访问研究数据;鉴于该产品由企业研发并供应,建议核实利益冲突申报是否完整、企业是否可能影响疗效与安全性的判断。AI 分析
原文没有说明试验期间出现不良事件时的报告与补偿机制,也没有说明研究结束后患儿如何获得长期随访和后续治疗;建议核实方案中对受试者的伤害赔偿、长期随访安排以及基因治疗产品未来可及性是否有明确约定。AI 分析
- AAV(腺相关病毒)
- 一种常被用作基因治疗"运输车"的病毒。把正常的基因装进它的外壳里,输进人体后把基因送到细胞中。
- 载体(vector)
- 基因治疗中用来把目的基因送进细胞的工具,这里指经过改造的AAV病毒颗粒。
- 中和抗体(NAbs)
- 体内原本就存在的一类抗体,会把AAV这类"运输车"认作外来物并把它清除掉,使治疗失效。
- IgG
- 血液中最主要的一类抗体。这里的IgG既可能妨碍AAV治疗,也是机体抵抗感染的重要成分。
- IdeS / GC801
- 一种来自化脓性链球菌的酶,能专门把IgG抗体"剪断"。GC801是经过工程改造的版本(imlifidase类),用于暂时清除IgG。
- GAA活性
- 酸性α-葡糖苷酶的活性,是庞贝病患者缺乏的酶。测定它的水平可以反映治疗是否让细胞重新产生了这种酶。
- IOPD(婴儿型庞贝病)
- 庞贝病中最严重的一种类型,通常在出生后不久发病,累及心肌和全身肌肉,病情进展快。
- IVIG(静脉注射免疫球蛋白)
- 从健康人血浆中提取的抗体制品,静脉输注。这里用来在IgG被清除后补充抗体,防止免疫力过低引起感染。
动画3 个
1. 作用机制:一步步看它怎么起作用已核对原文
GC801是一种工程化酶,能专门切断血液里的IgG抗体,让抗体暂时失去作用。
2. 时间线已核对原文
治疗开始前,患儿的血清IgG水平是6.25 g/L。
3. 利益相关方:谁承担风险、谁获益已核对原文
患儿的父母作为法定监护人,在入组前签署了知情同意书。
Front matter
GC801-enabled AAV gene therapy in a neonate with Pompe disease Jia Chen, M.D.,1,2 Wenhao Ma, Ph.D.,3,4 Hongbo Qi, M.D.,5 Xiuwei Ma, M.D.,1.2,6,7 Yanmei He, M.B.,1,2 Liu He, M.B.,1,2 Yan Ke, M.B.,1,2 Lu Zhuang, Ph.D.,1,2,6,7 Xinyang Jiang, M.Sc.,1,2,6,7 Jianhua Wang, M.D.,8 Juan Xu, M.Pharm.,9 Yan Xia, M.M.,3 Jianfang Zhou, M.D.,3 Yue Wang, M.D.,3,4 Xiaoyan Dong, M.D.,3 Xiaobing, Wu, M.D.,1,2 Zhichun Feng M.Med.1,2,6,7 1Department of Neonatology, Chinese People’s Liberation Army General Hospital, No. 5 Nanmencang, Dongcheng District, Beijing 100700, China.
2Department of Pediatrics, Chinese People’s Liberation Army General Hospital, No. 5 Nanmencang, Dongcheng District, Beijing 100700, China.
3Genecradle Therapeutics, No. 35 Jinghaisan Rd., Beijing Economic–Technological Development Area, Beijing 100176, China.
4Beijing Key Laboratory of Precision Diagnosis and Innovative Translational Research for Pediatric Rare Diseases, No. 56, Nanlishi Rd., Xicheng District, Beijing 100045, China.
5The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Rd., Chongqing 400016, China.
6National Engineering Laboratory for Birth Defects Prevention and Control of Key Technology, 5 Nanmencang, Dongcheng District, Beijing 100700, China.
7Beijing Key Laboratory of Pediatric Organ Failure, 5 Nanmencang, Dongcheng District, Beijing 100700, China.
8Ultrasonic Department, Seventh Medical Center of Chinese PLA General Hospital, No. 5 Nanmencang, Dongcheng District, Beijing 100700, China.
9Department of Pharmacy, Medical Supplies Center of Chinese People’s Liberation Army General Hospital, No. 5 Nanmencang, Dongcheng District, Beijing 100700, China.
Dr. Jia Chen, Wenhao Ma, and Hongbo Qi contributed equally to this article.
Correspondence to:
Xiaoyan Dong, M.D.
Genecradle Therapeutics, No. 35 Jinghaisan Rd., Beijing Economic–Technological Development Area, Beijing 100176, China. Email: dongxiaoyan@bj-genecradle.com Xiaobing, Wu, M.D.
Genecradle Therapeutics, No. 35 Jinghaisan Rd., Beijing Economic–Technological Development Area, Beijing 100176, China.
Beijing Key Laboratory of Precision Diagnosis and Innovative Translational Research for Pediatric Rare Diseases, No. 56, Nanlishi Rd., Xicheng District, Beijing 100045, China. Email: wuxiaobing@bj-genecradle.com Zhichun Feng M.Med.
Department of Pediatrics, Chinese People’s Liberation Army General Hospital, No. 5 Nanmencang, Dongcheng District, Beijing 100700, China. Email: zhichunfeng81@163.com
摘要Abstract
We report a neonate with IOPD who had high pre-existing anti-AAV9 antibody titers, which precluded eligibility for AAV9-mediated gene therapy (GC301). Preconditioning with a single dose of the IgG-degrading enzyme GC801 (0.2 mg/kg) safely reduced serum IgG from 6.25 g/L to a nadir of 0.72 g/L within 5 days. This pharmacological window facilitated successful GC301 vector transduction, driving a robust increase in GAA activity to 19.38 mmol/L/16h by day 84. Crucially, no adverse events beyond the underlying IOPD were observed. Our findings support the potential utility of GC801 as an agent to overcome pre-existing humoral barriers in neonatal gene therapy candidates.
Adeno-associated virus (AAV) vectors are a cornerstone of modern gene therapy,1,2 yet their efficacy is frequently undermined by pre-existing neutralizing antibodies (NAbs) against capsid proteins.3,4 Present in approximately one-third of the population, these NAbs trigger rapid vector clearance, creating a major translational bottleneck by excluding a large subset of patients from treatment.3-5 Existing mitigation strategies—such as plasmapheresis or FcRn antagonism—suffer from limitations including cost, off-target immunosuppression, and slow onset.5,6 The Streptococcus pyogenes–derived enzyme IdeS offers a compelling alternative by specifically cleaving the IgG hinge region, leading to immediate and irreversible IgG depletion.3 Although its recombinant form (imlifidase) is clinically approved for desensitization in adult kidney transplantation, and has shown promise against AAV8/AAV3B NAbs, its use in pediatric patients remains unexplored.7 This challenge is particularly acute in pediatric gene therapy, where early intervention is essential but often impeded by maternally derived antibodies.8 Here, we describe the first-in-neonate use of GC801, an engineered IdeS variant developed by Beijing Genecradle Therapeutics. Administered prior to AAV9 gene therapy for infantile-onset Pompe disease (IOPD), GC801 effectively mitigated pre-existing anti-AAV9 NAbs.
Result Subject Characteristics The diagnosis of IOPD was confirmed through integrated prenatal and postnatal evaluations: amniocentesis with whole exome sequencing identified compound heterozygous pathogenic GAA variants (c.1848C>G and c.2237G>A), while prenatal ultrasonography revealed progressive biventricular hypertrophy; postnatally, profoundly reduced plasma GAA activity (0.52–0.56 mmol/L/16h) and severe multisystemic involvement—including hypertrophic cardiomyopathy, sinus bradycardia, pulmonary hypertension, and renal and hepatic dysfunction—were observed (Table 1 and Figure 1A). Baseline biochemistry underscored the disease severity, with markedly elevated myocardial injury markers (NT-proBNP: 12,328 pg/mL; hs-Troponin: 19.91 pg/mL), significant skeletal muscle damage (CK: 2473 U/L; LDH: 1136 U/L), and metabolic disturbances (creatinine: 112.30 μmol/L; bilirubin: 80.60 μmol/L). Although AAV9-mediated GAA gene therapy was indicated based on our institutional experience, screening revealed high titers of anti-AAV9 binding (1:4174.2) and neutralizing antibodies (1:672.6), signifying a substantial pre-existing humoral barrier. Consequently, the patient received GC801 infusion to deplete systemic IgG, thereby establishing optimal transduction conditions for subsequent GC301 gene therapy.
Safety Profile GC801 was administered as a single intravenous infusion a dose of 0.2 mg/kg prior to GC301 gene therapy. Throughout the 2-week observation period (and extending into the 90-day follow-up), GC801 exhibited a favorable safety profile. No AEs attributable to GC801 were observed (Table 1).
Efficacy Profile GC801 concentrations peaked at 0.37 μg/mL 3 hours post-infusion, remained above 0.25 μg/mL at 50 hours, and declined to the lower limit of detection (LoD) by approximately day 14. This pharmacokinetic profile served as a key scientific rationale for establishing the 14-day safety and efficacy observation period (Figure 1B).
Serum IgG was 6.25 g/L at baseline. Following GC801 infusion, levels decreased to 2.41 g/L and 1.82 g/L at 24 and 48 hours, respectively (coinciding with GC301 administration at ~48 hours). By day 5 post-GC801, IgG further declined to 0.72 g/L. To mitigate complications of hypogammaglobulinemia, the infant received prophylactic IVIG (400 mg/kg) on day 7. This intervention raised IgG to 3.04 g/L by day 14, with concentrations subsequently stabilizing between 2.02 and 3.28 g/L for the remainder of the observation period (Figure 1C). Concurrent measurements of IgA and IgM demonstrated that GC801 selectively depleted IgG without affecting other immunoglobulin isotypes (Figure 1C). GAA activity increased from 9.67 mmol/L/16 h on day 28 to 19.38 mmol/L/16 h on day 84 post-GC301 infusion. This elevation not only restored GAA levels to within the reference range of healthy controls (11.21–52.14; median 18.17) but also suggested that GC801-mediated preemptive immunodepletion facilitates transgene-derived GAA expression (Figure 1D).
Post-treatment antibody responses The anti-AAV9 IgG responses exhibited an upward trend beginning 8 days post-GC301 infusion and were interpreted in two distinct phases: an initial modest rise (days 8–42), attributable to prophylactic IVIG infusion, followed by a subsequent steep rise (Figures 1E and 1F). Notably, data from four previously treated IOPD patients (aged 2.2–5.5 months) showed a similar kinetic profile. This indicates that GC801 conditioning did not substantially alter de novo antibody responses. Finally, serum anti-IdeS binding antibody analysis revealed a biphasic kinetic profile characterized by a transient elevation attributable to prophylactic IVIG infusion, flanked by periods during which levels remained below the LoD (Figure 1G).
讨论Discussion
This report describes the first-in-neonate application of GC801, an engineered IdeS protease, to overcome pre-existing humoral immunity against AAV9 capsids. Although IOPD provided the clinical context, the primary objective was to evaluate the safety and efficacy of GC801 as a desensitization platform for neonatal gene therapy; consequently, disease-specific outcomes (e.g., motor milestones or survival) fall outside the scope of this analysis.
GC801 demonstrated a highly favorable safety profile. A single intravenous dose of 0.2 mg/kg was not associated with any AEs attributable to the enzyme. Pharmacodynamically, GC801 induced rapid and profound IgG cleavage, reducing serum IgG from 6.25 g/L to a nadir of 0.72 g/L by day 5, thereby establishing a pharmacological window permissive for AAV9-mediated gene transfer. Crucially, this depletion was isotype-specific; IgA and IgM levels remained stable, preserving components of the neonatal immune repertoire.9 Transient hypogammaglobulinemia was effectively mitigated by prophylactic IVIG administered on day 7. These findings establish the feasibility of GC801 preconditioning in early neonates—a population previously unexplored for IdeS-based therapies.7,10 The increase in plasma GAA to 19.38 mmol/L/16h by day 84 (within the reference range of healthy controls) serves as a direct pharmacodynamic readout confirming successful AAV9-mediated transgene expression. This biochemical correction is mechanistically linked to GC801’s action: by cleaving circulating IgG, including pre-existing anti-AAV9 antibodies, GC801 prevented immediate vector neutralization and clearance, thereby enabling somatic cells transduction and sustained GAA production.4 Analysis of the immune response further delineates GC801’s immunologic footprint. Serum GC801 concentrations peaked at 0.37 μg/mL at 3 hours post-infusion and declined below the LoD by day 14, correlating with the transient nature of IgG depletion. Anti-IdeS antibody responses remained largely undetectable throughout the observation period; a transient, low-level elevation temporally aligned with IVIG administration likely reflected assay cross-reactivity with infused donor antibodies rather than de novo anti-drug antibodies.11 Importantly, the kinetics of de novo anti-AAV9 antibody development post-GC301 mirrored those in historical controls receiving GC301 without desensitization. This similarity indicates that GC801 preconditioning does not perturb subsequent humoral responses to the AAV9 capsid.12 In conclusion, GC801 represents a targeted strategy to mitigate pre-existing anti-AAV immunity in neonatal gene therapy candidates. Its favorable safety profile, rapid onset, and IgG specificity address key limitations of existing desensitization approaches, such as plasmapheresis or broad immunosuppression. Future studies are warranted to define optimal dosing windows and applicability across diverse AAV serotypes.
方法Methods
This single-arm, open-label, single-center investigator-initiated trial (Chinese Clinical Trial Registry identifier: ChiCTR2600120964 and ChiCTR2600120429) was designed to evaluate the safety and preliminary efficacy of GC801 for the depletion of pre-existing anti–AAV9 antibodies in pediatric patients who were otherwise ineligible for AAV-mediated gene therapy. The study protocol was approved by the Ethics Committee of the Chinese PLA General Hospital (approval number S2025-100-02 and S2026-036-02) and conducted in accordance with the Declaration of Helsinki. Written informed consent was obtained from the legal guardians of participant prior to enrollment. We planned to enroll three patients aged 0 to 8 years; the present report describes the sentinel case—a neonate with IOPD and pre-existing anti-AAV9 immunity. Eligible participants were required to have serum anti-AAV9 binding antibody titers ranging from 1:1000 to 1:10,000 (inclusive), with IgG levels within the normal age-adjusted range at screening. Key exclusion criteria included a history or family history of primary or secondary immunodeficiency, hypersensitivity to streptococcal or protease-derived agents, severe allergic reactions or anaphylaxis, significant intercurrent illness within 4 weeks before enrollment, vaccination within 2 weeks before enrollment, or any other condition deemed unsuitable by the investigator. Descriptive statistics were used to summarize all safety and efficacy data.
GC801, a cysteine protease variant derived from Streptococcus pyogenes IdeS and developed by Beijing Genecradle Therapeutics,1 was administered as a single intravenous infusion at a dose of 0.2 mg/kg. This agent mediates the rapid, transient cleavage of human IgG into F(ab') and Fc fragments, thereby disrupting its structural integrity and effector functions.1,2 Pharmacodynamic assessment was performed after GC801 administration; if total serum IgG decreased to less than 50% of baseline values, the patient proceeded to receive the GC301. GC301 is an AAV9 vector encoding codon-optimized human GAA complementary DNA and was administered intravenously at a dose of 1.2 × 10¹ vg/kg approximately 48 hours following GC801 infusion. Given the anticipated nadir in serum IgG following IdeS-mediated cleavage, with recovery expected to begin 48 to 72 hours post-treatment, intravenous immunoglobulin (IVIG) at a dose of 400 mg/kg was administered on day 7 to mitigate the risk of hypogammaglobulinemia-related complications. Patients were monitored intensively throughout the peri-infusion period according to the study protocol.
Safety evaluations included continuous vital sign monitoring, serial laboratory assessments, and systematic adverse event recording.3,4 Efficacy assessments comprised serial measurements of total serum IgG, anti-AAV9 binding antibodies, and neutralizing antibody titers at baseline and on days 1, 2, 7, and 14 post-GC801 administration. Serum concentrations of GC801/IdeS were quantified at 3, 8, and 50 hours and on days 8 and 17. Plasma GAA enzyme activity was measured at baseline (day 0) and on days 6, 14, 28, and 60 following GC301 infusion. Detailed assay methodologies have been described previously.1,3,4 GC801 and GC301 were supplied by Genecradle Therapeutics.1,3,4 Study design was collaborative between five academic investigators and four representatives from Genecradle Therapeutics. Data collection and analysis were performed jointly by the investigators and company representatives; however, Genecradle Therapeutics had no further role in data interpretation or manuscript preparation. All authors had full access to the study data and vouch for the accuracy and completeness of the data and the fidelity of the study to the protocol.
共找到 8 篇,点开看精读
前置研究0 篇
这篇研究建立在哪些工作之上
这一类没有找到。
相似研究8 篇
做类似事情的其他研究
后续研究0 篇
之后引用了这篇的研究
这一类没有找到。